Chapter 11 Summary of Parameter SettingsMS300
Pr.
Explanation
Stator Resistance (Rs) for
05-18
Induction Motor 2
Rotor Resistance (Rr) for
05-19
Induction Motor 2
Magnetizing Inductance
05-20
(Lm) for Induction Motor 2
Stator Inductance (Lx) for
05-21
Induction Motor 2
Multi-Motor (Induction)
05-22
Selection
Frequency for Y-
Connection / △-
05-23
Connection Switch for an
Induction Motor
Y-Connection / △-
05-24
Connection Switch for an
Induction Motor
Delay Time for Y-
Connection / △-Connection
05-25
Switch for an Induction
Motor
Accumulated Watt-Second
05-26
for a Motor in Low Word
(W-Msec.)
Accumulated Watt-Second
05-27
for a Motor in High Word
(W-Sec.)
Accumulated Watt-Hour
05-28
for a Motor (W-Hour)
Accumulated Watt-Hour
05-29
for a Motor in Low Word
(kW-Hour)
Accumulated Watt-Hour
05-30
for a Motor in High Word
(MW-Hour)
Accumulated Motor
05-31
Operation Time (Minutes)
Settings
0.000–65.535 
0.000–65.535 
0.0–6553.5 mH
0.0–6553.5 mH
1: Motor 1
2: Motor 2
3: Motor 3 (VF or SVC control mode only)
4: Motor 4 (VF or SVC control mode only)
0.00–599.00 Hz
0: Disable
1: Enable
0.000–60.000 sec.
Read only
Read only
Read only
Read only
Read only
0–1439
230
Default
Depending
on the
model
power
0.000
0.0
0.0
1
60.00
0
0.200
0.0
0.0
0.0
0.0
0.0
0