Chapter 12 Descriptions of Parameter SettingsMS300
Settings
Signal confirmation
29
for Y-connection
Signal confirmation
30
for -connection
31
High torque bias
32
Middle torque bias
33
Low torque bias
Disable writing
EEPROM function
38
(parameters
memory disable)
Torque command
39
direction
Force coasting to
40
stop
41
HAND switch
42
AUTO switch
Mechanical gear
48
ratio switch
49
Enable drive
Slave dEb action to
50
execute
Functions
When the control mode is V/F, ON: the drive operates by the
first V/F.
When the control mode is V/F, ON: the drive operates by the
second V/F.
Refer to Pr.11-30–11-32 for details.
ON: writing to EEPROM is disabled. Changed parameters are
not saved after power off.
For torque control (Pr.00-10 = 2), when the torque command is
AVI or ACI, ON: negative torque.
ON: during operation, the motor coasts to stop.
1. When the MI terminal switches to OFF, it executes a STOP
command. Therefore, if the MI terminal switches to OFF
during operation, the drive stops.
2. Use the optional keypad KPC-CC01 to switch between
HAND and AUTO. The drive stops first, and then switches
to HAND or AUTO status.
3. The optional digital keypad KPC-CC01 displays the current
status of the drive (HAND / OFF / AUTO).
ON: the mechanical gear ratio switches to the second group.
Refer to Pr.10-04–Pr.10-07 for details.
When the drive is enabled, the RUN command is valid.
When the drive is disabled, the RUN command is invalid.
When the drive is operating, the motor coasts to stop.
This function varies with MO = 45.
Enter the message setting in this parameter when the master
triggers dEb. This ensures that the slave also triggers dEb, then
the master and slave stop simultaneously.
Descriptions
bit 1
OFF
0
AUTO
0
HAND
1
OFF
1
302
bit 0
0
1
0
1