Chapter 8 Option CardsMS300
Environment
Noise Immunity
Operation / Storage
Shock / Vibration Resistance
8-4-4 Installation
Connecting the CMM-EIP02 to the Network
1. Turn off the power of the drive.
2. Open the front cover of the drive.
3. Connect the CAT-5e network cable to the RJ45 port of the
CMM-EIP02 (as shown in the right figure).
RJ45 PIN Definition
PIN
Signal
Positive pole for data
1
Tx+
Negative pole for data
2
Tx-
Positive pole for data
3
Rx+
4
--
Table 8-22
8-4-5 MS300 Communication Parameter Settings when Connecting to Ethernet
When you connect the MS300 to Ethernet, set up the communication parameters based on the table
below. The Ethernet master reads and writes the frequency command words and operation command
words after you set the communication parameters.
Parameters
Master frequency
00-20
command source
Operation
00-21
command source
Communication
09-30
decoding method
09-75
IP configuration
09-76
IP address 1
09-77
IP address 2
ESD (IEC 61800-5-1, IEC 61000-4-2)
EFT (IEC 61800-5-1, IEC 61000-4-4)
Surge Test (IEC 61800-5-1, IEC 61000-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6)
Operation: -10–50°C (temperature), 90% (humidity)
Storage: -25–70°C (temperature), 95% (humidity)
International standards:
IEC 61800-5-1, IEC 60068-2-6 / IEC 61800-5-1, IEC 60068-2-27
Definition
PIN
transmission
transmission
reception
N/C
Function
Current Setting Value
Signal
Definition
5
--
Negative pole for data
6
Rx-
reception
7
--
8
--
Table 8-23
The frequency command is controlled by the
8
communication card.
The operation command is controlled by the
5
communication card.
The decoding method for Delta AC motor
0
drive.
0: Static IP
0
1: Dynamic IP (DHCP)
192
IP address 192.168.1.5
168
IP address 192.168.1.5
162
Figure 8-32
N/C
N/C
Figure 8-33
N/C
Description
Table 8-21