Delta MS300 Series User Manual page 321

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

Chapter 12 Descriptions of Parameter SettingsMS300
Settings
Functions
66
SO output logic A
68
SO output logic B
Analog input level
67
reached
73
Over-torque 3
74
Over-torque 4
75
Forward RUN status
76
Reverse RUN status
02-18
Multi-Function Output Direction
Settings
 This parameter is in hexadecimal.
 This parameter is set by a bit. If the bit is 1, the corresponding multi-function output acts in an
opposite way.
Example: Assume Pr.02-13 = 1 (indication when the drive is operating). If the output is positive,
and the bit is set to 0, then Relay is ON when the drive runs and is OFF when the drive stops.
On the contrary, if the output is negative, and the bit is set to 1, then the Relay is OFF when the
drive runs and is ON when the drive stops.
bit 4
MO2
Status of the
Normal
STL1–STL3
The multi-function output terminals operate when the analog
input level is between the high level and the low level.
Pr.03-44: Select one of the analog input channels (AVI, ACI) to
Pr.03-45: The high level for the analog input, default is 50%.
Pr.03-46: The low level for the analog input, default is 10%.
If analog input > Pr.03-45, the multi-function output terminal
operates. If analog input < Pr.03-46, the multi-function output
terminal stops output.
Activates when over-torque is detected. Pr.14-75 sets the over-
torque detection level. Pr.14-76 sets the over-torque detection
time (refer to Pr.14-74–14-76).
Activates when over-torque is detected. Pr.14-78 sets the over-
torque detection level. Pr.14-79 sets the over-torque detection
time (refer to Pr
When the drive runs FWD, the output terminal for forward
running is closed; when the drive stops, the output terminal for
forward running is open.
When the drive runs REV, the output terminal for reverse running
is closed; when the drive stops, the output terminal for reverse
running is open.
0000h–FFFFh (0:N.O.; 1:N.C.)
bit 3
bit 2
MO1
Reserved
Reserved
Descriptions
Status of the Safety Output
Drive
Status A (MO = 66)
Broken circuit (open)
STO
Short circuit (closed)
Short circuit (closed)
be compared.
14-77–14-79).
.
bit 1
bit 0
RY
312
Status B (MO = 68)
Short circuit (closed)
Broken circuit
(open)
Broken circuit
(open)
Default: 0000h