Chapter 16 PLC Function ApplicationsMS300
Command
ANI
Connect contact B in series
X0–X17
Operand
Use the ANI command to create a series connection to contact B; its function is to first
read the current status of the designated series contact and the logical operation results
before contact in order to perform "AND" operation; saves the results in the cumulative
register.
Ladder diagram:
Command
OR
Connect contact A in parallel
X0–X17
Operand
Use the OR command to establish a parallel connection to contact A; its function is to
first read the current status of the designated series contact and the logical operation
results before contact in order to perform "OR" operation; saves the results in
cumulative register.
Ladder diagram:
Command
ORI
Connect contact B in parallel
X0–X17
Operand
Use the ORI command to establish a parallel connection to contact B; its function is to
first read the current status of the designated series contact and the logical operation
results before contact in order to perform "OR" operation; saves the results in
cumulative register.
Ladder diagram:
Y0–Y17
Y0–Y17
X0
X1
Y0–Y17
X0
X1
Function
M0–M799
T0–159
Command code:
LD
ANI
OUT
Function
M0–M799
T0–159
Command code:
LD
Y1
OR
OUT
Function
M0–M799
T0–159
Command code:
LD
Y1
ORI
OUT
696
C0–C79
D0–D399
Description:
X1
Load Contact A of X1
Create a series
connection to contact
X0
B of X0
Y1
Drive Y1 coil
C0–C79
D0–D399
Description:
X0
Load Contact A of X0
Create a series
X1
connection to contact
A of X1
Y1
Drive Y1 coil
C0–C79
D0–D399
Description:
X0
Load Contact A of X0
Create a series
X1
connection to contact
B of X1
Y1
Drive Y1 coil