Chapter 16 PLC Function ApplicationsMS300
API
GRY
170
D
bit device
X
Y
M
S
D
Notes on operand usage:
Refer to the function specifications table for each device in series
for the scope of device usage.
P
Word device
K
H
KnX KnY KnM
S: source device. D: device storing GRAY code.
Converts the BIN value of the device designated by S to a GRAY code, and stores
the result in the device designated by D.
The valid range for S is as shown below; if you exceed this range, it is an error, and
the command does not execute.
16-bit command: 0–32,767
32-bit command: 0–2,147,483,647
When X0 = ON, converts the constant K6513 to a GRAY code and stores it in D0.
Convert BIN to GRAY code
16-bit command (5 STEP)
T
C
D
GRY
32-bit command (9 STEP)
DGRY
Flag signal: none
744
Continuous
GRYP
execution type
execution type
Continuous
DGRYP
execution type
execution type
Pulse
Pulse