Initialize Data File

Operation
1 Turn ON the power supply
again while pressing [MAIN
MENU] simultaneously.
2 Change the security mode to
the management mode.
3 Select {FILE} under the main
menu.
4 Select {INITIALIZE}.
5 Select {FILE/GENERAL
DATA}.
6 Select the data file to be initial-
ized.
7 Press [ENTER].
8 Select {YES}.
The INITIALIZE window appears.
INITIALIZE
TOOL DATA
WEAVING DATA
USER COORDINATE DATA
VARIABLE DATA
ARC START COND DATA
ARC END COND DATA
ARC AUXILIARY COND DATA
POWER SOURCE COND. DATA
USR DEF WELDER COND DATA
SHOCK DETECTION LEVEL
Main Menu
Short Cut
The selected data file/general data are marked with " ".
The parameters marked with " " cannot be selected.
INITIALIZE
TOOL DATA
WEAVING DATA
USER COORDINATE DATA
VARIABLE DATA
ARC START COND DATA
ARC END COND DATA
ARC AUXILIARY COND DATA
POWER SOURCE COND. DATA
USR DEF WELDER COND DATA
SHOCK DETECTION LEVEL
A confirmation dialog box appears.
INITIALIZE
TOOL DATA
WEAVING DATA
USER COORDINATE DATA
VARIABLE DATA
ARC START COND DATA
ARC END COND DATA
ARC AUXILIARY COND DATA
POWER SOURCE COND. DATA
USR DEF WELDER COND DATA
SHOCK DETECTION LEVEL
Main Menu
Short Cut
The selected data file/general data are initialized.
8-105
8.18 File Initialize
Explanation
TOOL
. CND
WEAV
. CND
UFRAME
. CND
VAR
. DAT
ARCSRT
. CND
ARCEND
. CND
ARCSUP
. DAT
WELDER
. DAT
WELDUDEF
. DAT
SHOCKLVL
. CND
Maintenance mode
TOOL
. CND
WEAV
. CND
UFRAME
. CND
VAR
. DAT
ARCSRT
. CND
ARCEND
. CND
ARCSUP
. DAT
WELDER
. DAT
WELDUDEF
. DAT
SHOCKLVL
. CND
TOOL
. CND
WEAV
. CND
UFRAME
. CND
VAR
. DAT
ARCSRT
. CND
I n i t i a l i z e ?
ARCEND
. CND
ARCSUP
. DAT
WELDER
. DAT
YES
NO
WELDUDEF
. DAT
SHOCKLVL
. CND
Maintenance mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents