Logical
Input Name / Function
Number
20010
EXTERNAL START
Functions the same as the [START] button in
the programming pendant. Only the rising edge
of the signal is valid. It starts robot operation
(playback). This signal is invalid if external start
is prohibited from the playback condition dis-
play.
20012
CALL MASTER JOB
Only the rising edge of the signal is valid. It
calls up the top of the robot program, that is the
top of the master job
during playback, during teach-lock and when
play master or call is prohibited (set from the
playback operation condition display).
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the
cause been corrected, this signal resets the
alarm or error.
20015
SELECT PLAY MODE
The play mode is selected when the mode key
on the programming pendant is set at
"REMOTE". Only the rising edge of the signal
is valid. When this selection signal assigned
concurrently with other mode selection signal,
the teach mode is selected on a priority basis.
The signal is invalid while EXTERNAL MODE
SWITCH is prohibited.
20016
SELECT TEACH MODE
The teach mode is selected when the mode
key of the programming pendant is set at
"REMOTE". The other mode selection is
unavailable when this signal is ON; the signal
is selected by priority even when the other
selection signal is ON, enabling the teach
mode selection.
20020
INTERFERENCE 1 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube
*2
1
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
20021
INTERFERENCE 2 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube
*2
2
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
20022
WELDING ON/OFF (From sequencer)
This signal inputs the welding ON/OFF selector
switch status from the sequencer in the inter-
lock unit. The WELD ON/OFF signal is output
to the Power Source according to this signal
and the manipulator status.
System Input List NIO01 (Spot Welding)
Number
20023
20024
*1
. This signal is invalid
20025
20050
*4
20051
*4
20052
*4
20053
*4
*3
13-60
13.6 User I/O Signal Assignment
Logical
Input Name / Function
WELDING PAUSE (From sequencer)
This signal is used to move the manipulator to
the home position when an error occurs in the
Power Source or the gun.
The robot ignores the spot welding instruction
and operates playback motion.
INTERFERENCE 3 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube
*2
3
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
INTERFERENCE 4 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube
*2
4
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
TIMER COOLING WATER ERROR
This signal monitors the status of timer cooling
water. The manipulator displays alarm and
stops when this signal is input. The servo
power remains ON.
GUN COOLING WATER ERROR
This signal monitors the status of gun cooling
water. The manipulator displays alarm and
stops when this signal is input. The servo
power supply remains ON.
TRANSTHERMO ERROR
Error signal is sent from the transformer in the
gun to the robot. This signal is ON normally
(NC) and an alarm occurs when the signal is
OFF. The servo power supply remains ON.
LOW AIR PRESSURE
When air pressure is reduced and this input is
turned ON, an alarm occurs. The servo power
supply remains ON.
WELD COMPLETION
This signal indicates that the Power Source
completed welding without error. This signal is
used as a confirmation signal for welding
instruction execution and manual spot welding.
After this signal is input, the welding sequence
is completed and the next step is executed
when confirmation limit switch is not provided.