YASKAWA NX100 Instructions Manual page 272

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

13.4 Contact Output of Emergency Stop Button
13.4 Contact Output of Emergency Stop Button
The contact output terminals for the emergency stop button on the programming pendant and
the door front are provided on the terminal board 2XT (screw size M3.5) on NX100.
These contact outputs are always valid no matter of the NX100 main power supply status ON
or OFF. (Status output signal: normally closed contact)
• Do not use the emergency stop button with 24 VAC, 0.5 A or more.
Failure to observe this instruction may result in damage to equipment.
Front door of NX100
Emergency stop button
Programming pendant
Emergency stop button
CAUTION
2XT
PBESP3+
PBESP3−
PBESP4+
PBESP4−
PPESP3+
PPESP3−
PPESP4+
PPESP4−
13-33
EXT
PBESP3+
PBESP3−
PBESP4+
PBESP4−
PPESP3+
PPESP3−
PPESP4+
PPESP4−

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents