Interfaces
1. Log into the Connect IT Mini command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Configure SureLink on ETH:
a. Set the interval to ten seconds:
(config)> network interface eth ipv4 surelink interval 10s
(config)>
b. Delete the existing test targets:
(config network interface eth> del ipv4 surelink target 0
(config network interface eth> del ipv4 surelink target 1
(config network interface eth)>
c. Add a test target:
(config)> add network interface eth ipv4 surelink target end
(config network interface eth ipv4 surelink target 0)>
d. Set the probe type to ping:
(config network interface eth ipv4 surelink target 0)> test ping
(config network interface eth ipv4 surelink target 0)>
e. Set the packet size to 256 bytes:
(config network interface eth ipv4 surelink target 0)> ping_size 256
(config network interface eth ipv4 surelink target 0)>
f. Set the host to ping:
(config network interface eth ipv4 surelink target 0)> ping_host 43.66.93.111
(config network interface eth ipv4 surelink target 0)>
3. Repeat the above step for the cellular Modem (modem) interface to enable SureLink on that
interface.
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.