Digi Connect IT Mini User Manual page 360

Hide thumbs Also See for Connect IT Mini:
Table of Contents

Advertisement

Applications
network.interface.lan1.device=/network/bridge/lan1
network.interface.lan1.enable=true
network.interface.lan1.ipv4.address=192.168.2.1/24
network.interface.lan1.ipv4.connection_monitor.attempts=3
...
>>> interfaces = cfg.get("network.interface")
>>> print(interfaces.keys())
['defaultip', 'defaultlinklocal', 'lan1', 'loopback', 'wan1', 'wwan1', 'wwan2']
>>> print(interfaces.get("lan.ipv4.address"))
192.168.2.1/24
>>>
Modify the device configuration
Use the set() and commit() methods to modify the device configuration:
1. Log into the Connect IT Mini command line as a user with shell access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type shell to access the device shell.
2. At the shell prompt, use the python command with no parameters to enter an interactive
Python session:
# python
Python 3.6.10 (default, Jan 31 2020, 08:45:19)
[GCC 8.3.0] on linux
Type "help", "copyright", "credits" or "license" for more information.
>>>
3. Import the config submodule:
>>> from digidevice import config
>>>
4. Use config.load(writable=True) to enable write mode for the configuration:
>>> cfg = config.load(writable=True)
>>>
5. Use the set() method to make changes to the configuration:
>>> cfg.set("system.name", "New-Name")
>>>
6. Use the commit() method to save the changes:
>>> cfg.commit()
True
>>>
7. Use the get() method to verify the change:
Digi Connect IT® Mini User Guide