System administration
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Schedule system maintenance:
a. Configure the time of day that the maintenance window should start, using the syntax
HH:MM. If the start time is not set, maintenance tasks are not scheduled and will not be
run.
(config)> system schedule maintenance from HH : MM
(config)>
The behavior of the start time varies depending on the setting of the duration length,
which is configured in the next step.
n
n
n
n
b. Configure the duration length (the amount of time that the maintenance tasks will be run).
If 0 is used, all scheduled tasks will begin at the start time, defined in the previous step.
system schedule maintenance length num
(config)>
where num is any whole number between 0 and 24.
c. Configure the frequency that the maintenance tasks should be run:
system schedule maintenance frequency value
(config)>
where value is either daily or weekly. Daily is the default.
d. Configure the device to look for any updated modem firmware during the maintenance
window. If updated firmware is found, it will then be installed. The device will look for
updated firmware both on the local device and over the network, using either a WAN or
cellular connection.
system schedule maintenance modem_fw_update value
(config)>
Digi Connect IT® Mini User Guide
If the duration length is set to 0, all scheduled tasks will begin at the exact time
specified in the start time.
If the duration length is set to 24 hours, the start time is effectively obsolete and
the maintenance tasks will be scheduled to run at any time. Setting the duration
length to 24 hours can potentially overstress the device and should be used with
caution.
If the duration length is set to any value other than to 0 or 24 hours, the
maintenance tasks will run at a random time during the time allotted for the
duration window.
If the duration length is set to one or more hours, the minutes field in the start time
is ignored and the duration window will begin at the beginning of the specified hour.