Serial port
7. Click to expand Service Settings. Within this section you can enable SSH, TCP, or Telnet. This
section is available only if the Remote Access mode is selected.
SSH: Allow the serial port to be directly accessed using an SSH connection.
n
a. Click Enable SSH.
b. In the IP Port field, enter the IP port number on which the device will listen for SSH
c. Click Enable mDNS to enable mDNS reporting for the SSH service.
TCP: Allow the serial port to be directly accessed using a TCP connection.
n
a. Click Enable TCP.
b. In the IP Port field, enter the IP port number on which the device will listen for TCP
c. Click Enable mDNS to enable mDNS reporting for the TCP service.
Telnet: Allow the serial port to be directly accessed using a Telnet connection.
n
a. Click Enable Telnet.
b. In the IP Port field, enter the IP port number on which the device will listen for
c. Click Enable mDNS to enable mDNS reporting for the Telnet service.
8. Click to expand Session Settings. Within this section you can configure the session
parameters. This section is available only if the Remote Access mode is selected.
Click Exclusive Access if access should be limited to a single active session.
n
For Escape Sequence, enter the characters that can be used to start an escape
n
sequence.
For History Size, enter the number of bytes of output from the serial port to buffer.
n
For Idle Timeout, enter the amount of time that the active session can be idle before
n
the user is automatically logged out. Enter 0s to disable the idle timeout feature.
9. Click to expand Monitor Settings. This section is available only if the Remote Access mode is
selected.
Click CTS Changes to monitor CTS (Clear To Send) changes on this port.
n
Click DCD Changes to monitor DCD (Data Carrier Detect) changes on this port.
n
10. Click Apply to save the configuration and apply the change.
Digi Connect IT® Mini User Guide
connections. The range is 1-65535.
connections. The range is 1-65535.
Telnet connections. The range is 1-65535.
Configure the serial port