Info-Center Timestamp - Huawei Quidway S2000 Series Command Manual

Table of Contents

Advertisement

Command Manual - System Management
Quidway S2000 Series Ethernet Switches
default log, trap and debugging settings in the records may be different with one
another. Use default configuration record if a module does not have any specific
configuration record in the channel.
Example
# Configure to enable the log information of VLAN module in SNMP channel and allows
the output of the information with a level higher than emergencies.
[Quidway] info-center source vlan channel snmp log level emergencies

4.5.12 info-center timestamp

Syntax
info-center timestamp { log | trap | debugging } { boot | date | none }
undo info-center timestamp { log | trap | debugging }
View
System view
Parameter
log: Log information.
trap: Trap information.
debugging: Debugging information.
boot: Time elapsing after system starts. Format: xxxxxx.yyyyyy, xxxxxx is the high 32
bits of the elapsed time (in milliseconds) after system starts, and yyyyyy is the low 32
bits.
date: Current system date and time. It shows as yyyy/mm/dd-hh:mm:ss in Chinese
environment and mm/dd/yyyy-hh:mm:ss in Western language environment.
none: No timestamp format.
Description
Using info-center timestamp command, you can configure the timestamp output
format in debugging/trap information. Using undo info-center timestamp command,
you can disable the output of timestamp field.
By default, datetime stamp is used.
Chapter 4 System Maintenance Commands
4-32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents