O5: Log Function - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

2.11 o: Keypad-Related Settings
o4-23: Date Format
No.
Name
(Hex.)
o4-23
Date Format
(1550)
RUN
Sets the date format that the drive uses for the fault history and other records.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
Note:
The Fault History in the Monitor Mode shows when faults occurred. Refer to
o4-24: bAT Detection Selection
No.
Name
(Hex.)
o4-24
bAT Detection Selection
(310F)
RUN
0 : Disable
The drive will not detect bAT or TiM.
1 : Enable (Alarm Detected)
TiM or bAT shows on the keypad, and operation continues. The output terminal set for Alarm [H2-01 to H2-03 = 10]
activates.
2 : Enable (Fault Detected)
The drive output shuts off and the motor coasts to stop. Fault relay output terminal MA-MC activates, and MB-MC
deactivates.

o5: Log Function

The data log function saves drive status information as a CSV file in the micro SD memory card in the keypad.
Monitors Ux-xx are the source of data log information. You can record a maximum of 10 monitors.
Change the LCD keypad screen from the main menu to the Diagnostic Tools screen and select the data log function.
Set the number of the monitor to record and the sampling time, then start to record the data log.
No.
o5-03
Log Monitor Data 1
o5-04
Log Monitor Data 2
o5-05
Log Monitor Data 3
o5-06
Log Monitor Data 4
o5-07
Log Monitor Data 5
o5-08
Log Monitor Data 6
o5-09
Log Monitor Data 7
o5-10
Log Monitor Data 8
o5-11
Log Monitor Data 9
o5-12
Log Monitor Data 10
526
V/f
CL-V/f
OLV
CLV
AOLV
Sets the date display format. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM [Keypad Time Not
Set].
Table 2.74 Setting Parameters for Data Log Items
Name
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Show Fault History on page 573
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
101
U1-01 [Frequency Reference]
102
U1-02 [Output Frequency]
103
U1-03 [Output Current]
107
U1-07 [DC Bus Voltage]
108
U1-08 [Output Power]
000
Not selected
000
Not selected
000
Not selected
000
Not selected
000
Not selected
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
(Range)
2
(0 - 2)
for more information.
Default
(Range)
0
(0 - 2)
Data Log Monitors

Advertisement

Table of Contents
loading