YASKAWA GA800 Programming Manual page 37

Ac drive for industrial applications
Table of Contents

Advertisement

No.
Name
(Hex.)
C5-27
Motor 2 ASR Gain
Switchover Freq
(035C)
C5-28
Motor 2 ASR Integral
Limit
(035D)
C5-29
Speed Control Response
(0B18)
Expert
C5-32
Motor 2 Integral Oper at
Acc/Dec
(0361)
C5-37
Motor 2 Inertia
(0278)
Expert
C5-38
Motor 2 Load Inertia
Ratio
(0279)
Expert
C5-39
ASR Primary Delay Time
Const 2
(030D)
C5-50
Notch Filter Frequency
(0B14)
Expert
C5-51
Notch Filter Bandwidth
(0B15)
Expert
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency where the drive will switch between these parameters:
C5-21 and C5-23 [Motor 2 ASR Proportional Gain 1/2]
C5-22 and C5-24 [Motor 2 ASR Integral Time 1/2]
V/f
CL-V/f
OLV
CLV
AOLV
Set the upper limit of the motor 2 ASR integral amount as a percentage of the rated load.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level of speed control responsiveness. Usually it is not necessary to change this
setting.
0 : Standard
1 : High Performance 1
V/f
CL-V/f
OLV
CLV
AOLV
Sets ASR integral operation during acceleration and deceleration for motor 2.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor inertia for motor 2.
Note:
The default settings and the display units for setting ranges are different for different
drive models.
• 0.0001 kgm
2
units (setting range: 0.0001 kgm
to 4012
• 0.001 kgm
2
units (setting range: 0.001 kgm
4103
• 0.01 kgm
2
units (setting range: 0.01 kgm
4720
V/f
CL-V/f
OLV
CLV
AOLV
Sets the load inertia ratio for the motor 2 inertia.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant used when the torque reference is output from ASR. Usually it
is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the machine resonance frequency.
Note:
Set C5-50 = 0 [0 Hz] to disable the notch filter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the notch width of the notch filter.
Note:
Set C5-50 = 0 [Notch Filter Frequency = 0 Hz] to disable the notch filter.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2
to 6.0000 kgm
2
): 2004 to 2021, 4002
2
2
to 60.000 kgm
): 2030 to 2211, 4018 to
2
to 600.00 kgm
2
): 2257 to 2415, 4140 to
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
1.6 C: Tuning
Default
Ref.
(Range)
0.0
267
(0.0 - 400.0)
400%
268
(0 - 400%)
0
268
(0, 1)
0
268
(0, 1)
Determined by o2-04,
268
C6-01
(0.0001 - 600.00 kgm
2
)
1.0
269
(0.0 - 6000.0)
0.000 s
269
(0.000 - 0.500 s)
0 Hz
269
(0, or 2 to 100 Hz)
1.0
269
(0.5 - 5.0)
37
1

Advertisement

Table of Contents
loading

Table of Contents