YASKAWA GA800 Programming Manual page 493

Ac drive for industrial applications
Table of Contents

Advertisement

n4-69: Flux Control Response
No.
Name
(Hex.)
n4-69
Flux Control Response
(1B89)
If step-out occurs when the load changes, decrease the setting value in 1.00 increments.
Note:
If heavy loads decrease motor speed, increase the setting value in 1.00 increments. If it does not get better, increase n4-74 [Limit of Flux
Loop] in 20% increments.
n4-70: Speed Command Comp @ Low Freq
No.
Name
(Hex.)
n4-70
Speed Command Comp @
Low Freq
(1B8A)
This function makes the control more stable when operating at low speeds. Increase the setting in 0.3 Hz increments
at the time of low-speed references with no load.
Note:
If you increase this parameter to make the speed references for low speeds more stable, it can make the speed control less accurate.
n4-71: Flux Estimation Method
No.
Name
(Hex.)
n4-71
Flux Estimation Method
(1B8B)
Expert
0 : Method 1
1 : Method 2
n4-72: Speed Feedback Mode
No.
Name
(Hex.)
n4-72
Speed Feedback Mode
(1B8C)
You can connect a PG-B3 or PG-X3 encoder option in AOLV control. You can use the encoder option for better speed
control precision.
Note:
• When you use an encoder option in AOLV control to operate machinery, specialized tuning of the drive can be necessary. You should
usually set A1-02 = 3 [Control Method Selection = Closed Loop Vector] when you use an encoder option.
• When you set this parameter to 1, also set the number of PG pulses in F1-01 [Encoder 1 Pulse Count (PPR)].
0 : Without Encoder
1 : With Encoder
n4-73: PGo Recovery Selection
No.
Name
(Hex.)
n4-73
PGo Recovery Selection
(1B8D)
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Unifies control of magnetic flux to make motor vibrations more stable.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to make the drive more stable when operating at low speeds. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the flux estimation method. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the requirement for an encoder option when A1-02 = 4 [Control Method Selection = Advanced
Open Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the restart mode to Without Encoder Mode or the With Encoder Mode when an encoder is
disconnected.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.10 n: Special Adjustment
Default
(Range)
1.00
(0.00 - 60.00)
Default
(Range)
1.00 Hz
(0.00 - 6.00 Hz)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
2
493