YASKAWA GA800 Programming Manual page 507

Ac drive for industrial applications
Table of Contents

Advertisement

n8-64: Output Voltage Limit I Time
No.
Name
(Hex.)
n8-64
Output Voltage Limit I Time
(057F)
Expert
n8-65: Speed Fdbk Gain @ oV Suppression
No.
Name
(Hex.)
n8-65
Speed Fdbk Gain @ oV
Suppression
(065C)
Expert
Adjust this parameter in these conditions:
• If there is resonance or hunting when you use the overvoltage suppression function, increase the setting value.
• If motor response is low when you use the overvoltage suppression function, decrease the setting value in 0.05-unit
increments.
n8-66: Output Voltage Limit Filter Time
No.
Name
(Hex.)
n8-66
Output Voltage Limit Filter
Time
(0235)
Expert
n8-69: Speed Observer Control P Gain
No.
Name
(Hex.)
n8-69
Speed Observer Control P
Gain
(065D)
Expert
n8-70: Speed Observer Control I Time
No.
Name
(Hex.)
n8-70
Speed Observer Control I
Time
(065E)
Expert
n8-71: Speed Observer Control D Gain
No.
Name
(Hex.)
n8-71
Speed Observer Control D
Gain
(065F)
Expert
n8-72: Speed Estimation Method Select
No.
Name
(Hex.)
n8-72
Speed Estimation Method
Select
(0655)
Expert
0 : Method 1
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time for output voltage control. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of internal speed feedback detection suppression while the overvoltage suppression
function is operating as a magnification value. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant for output voltage control. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain that the drive uses for speed estimation. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed estimator integral time constant. It is available when n8-72 = 1 [Speed Estimation
Method Select = Method 2]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Set the speed estimator differential gain. It is available when n8-72 = 1 [Speed Estimation Method
Select = Method 2]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the speed estimation method. Usually it is not necessary to change this setting.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.10 n: Special Adjustment
Default
(Range)
0.040 s
(0.000 - 5.000 s)
Default
(Range)
1.50
(0.00 - 10.00)
Default
(Range)
0.020 s
(0.000 - 5.000 s)
Default
(Range)
1.00
(0.00 - 20.00)
Default
(Range)
0.0 s
(0.0 - 100.0 s)
Default
(Range)
5.00
(0.00 - 50.00)
Default
(Range)
1
(0, 1)
2
507