1.17 U: Monitors
No.
Name
(Hex.)
U6-06
OutputVoltageRef: Vd
(005A)
U6-07
q-Axis ACR Output
(005F)
Expert
U6-08
d-Axis ACR Output
(0060)
Expert
U6-09
AdvPhase Compen Δθcmp
(07C0)
Expert
U6-10
ContAxisDeviation Δθ
(07C1)
Expert
U6-13
MagPolePosition(Enc)
(07CA)
Expert
U6-14
MagPolePosition(Obs)
(07CB)
Expert
U6-17
Energy Save Coeff
(07D1)
Expert
U6-18
Enc 1 Pulse Counter
(07CD)
U6-19
Enc 2 Pulse Counter
(07E5)
U6-20
UP/DOWN 2 Bias Value
(07D4)
U6-21
Offset Frequency
(07D5)
U6-22
ZeroServo Pulse Move
(0062)
U6-25
ASR Output Level
(006B)
Expert
U6-26
Feed Fwd Cont Output
(006C)
Expert
U6-27
FeedFwd Estimate Spd
(006D)
Expert
122
V/f
CL-V/f
OLV
CLV
AOLV
Shows the drive internal voltage reference for motor excitation current control (d axis).
Unit: 0.1 V
V/f
CL-V/f
OLV
CLV
AOLV
Shows the output value for current control related to motor secondary current (q axis).
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the output value for current control related to motor excitation current (d axis).
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the data on forward phase compensation for the calculation results of the amount of control
axis deviation.
Unit: 1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the deviation between the γδ-Axis used for motor control and the dq-Axis.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value of the flux position detection.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value of the flux position estimation.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the total time of direction of motor rotation detections for Speed Estimation Speed Searches.
This value adjusts b3-26 [Direction Determination Level].
Note:
Upper limit is +32767 and lower limit is -32767.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of pulses for speed detection (PG1).
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of pulses for speed detection (PG2).
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the bias value used to adjust the frequency reference.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the total value of d7-01 to d7-03 [Offset Frequency 1 to 3] selected with Add Offset
Frequency 1 to 3 [H1-xx = 44 to 46].
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the distance that the rotor moved from its last position when Zero Servo is available. The
value shown in this monitor = 4 X [No. of PG pulses].
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the primary delay filter input value of the ASR (speed control loop).
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the Feed Forward control output.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the feed forward estimated speed.
Unit: 0.01%
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
MFAO Signal Level
200 V class: 10 V = 200
Vrms
400 V class: 10 V = 400
Vrms
(-10 V to +10 V)
200 V class: 10 V = 200
Vrms
400 V class: 10 V = 400
Vrms
(-10 V to +10 V)
200 V class: 10 V = 200
Vrms
400 V class: 10 V = 400
Vrms
(-10 V to +10 V)
10 V: 180 ° (-10 V to +10 V)
10 V: 180 ° (-10 V to +10 V)
10 V: 180° (-10 V to +10 V)
10 V: 180 ° (-10 V to +10 V)
No signal output available
10 V: 65536
10 V: 65536
10 V: Maximum Frequency
10 V: Maximum Frequency
10 V = Number of pulses per
revolution (-10 V to +10 V)
10 V = Motor secondary
rated current (-10 V to +10
V)
10 V = Motor secondary
rated current (-10 V to +10
V)
10 V = Maximum frequency
(-10 V to +10 V)