YASKAWA GA800 Programming Manual page 221

Ac drive for industrial applications
Table of Contents

Advertisement

Figure 2.33 Example of How the Timer Function Works with H2-01 Terminals
Note:
When the terminal is triggered, it continues for a minimum of 100 ms. The on/off-delay time of MFDO terminal does not have an effect.
b4-01: Timer Function ON-Delay Time
No.
Name
(Hex.)
b4-01
Timer Function ON-Delay
Time
(01A3)
b4-02: Timer Function OFF-Delay Time
No.
Name
(Hex.)
b4-02
Timer Function OFF-Delay
Time
(01A4)
b4-03: Terminal M1-M2 ON-Delay Time
No.
Name
(Hex.)
b4-03
Terminal M1-M2 ON-Delay
Time
(0B30)
Expert
b4-04: Terminal M1-M2 OFF-Delay Time
No.
Name
(Hex.)
b4-04
Terminal M1-M2 OFF-Delay
Time
(0B31)
Expert
b4-05: Terminal M3-M4 ON-Delay Time
No.
Name
(Hex.)
b4-05
Terminal M3-M4 ON-Delay
Time
(0B32)
Expert
b4-06: Terminal M3-M4 OFF-Delay Time
No.
Name
(Hex.)
b4-06
Terminal M3-M4 OFF-Delay
Time
(0B33)
Expert
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ON-delay time for the timer input.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the OFF-delay time for the timer input.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time until the contact is turned ON after the function set with H2-01 turns ON.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to deactivate the contact after the function set in H2-01 deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to activate the contact after the function set in H2-02 activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to deactivate the contact after the function set in H2-02 deactivates.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.3 b: Application
Default
(Range)
0.0 s
(0.0 - 3000.0 s)
Default
(Range)
0.0 s
(0.0 - 3000.0 s)
Default
(Range)
0 ms
(0 - 65000 ms)
Default
(Range)
0 ms
(0 - 65000 ms)
Default
(Range)
0 ms
(0 - 65000 ms)
Default
(Range)
2
0 ms
(0 - 65000 ms)
221