o5-10: Log Monitor Data 8
No.
Name
(Hex.)
o5-10
Log Monitor Data 8
(155A)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-01 [Frequency Reference], set o5-10 = 101. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-11: Log Monitor Data 9
No.
Name
(Hex.)
o5-11
Log Monitor Data 9
(155B)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-01 [Frequency Reference], set o5-11 = 101. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-12: Log Monitor Data 10
No.
Name
(Hex.)
o5-12
Log Monitor Data 10
(155C)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-01 [Frequency Reference], set o5-12 = 101. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
2.11 o: Keypad-Related Settings
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
112
(000, 101 - 999)
Default
(Range)
000
(000, 101 - 999)
Default
(Range)
000
(000, 101 - 999)
2