2.7 F: Options
F7-12: Gateway Address 4
No.
Name
(Hex.)
F7-12
Gateway Address 4
(03F0)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-13: Address Mode at Startup
No.
Name
(Hex.)
F7-13
Address Mode at Startup
(03F1)
0 : Static
1 : BOOTP
2 : DHCP
Note:
• The following setting values are available when using the PROFINET communication option card (SI-EP3).
–0: Static
–2: DCP
• When F7-13 = 0, set parameters F7-01 to F7-12 [IP Address 1 to Gateway Address 4] to set the IP Address. Be sure to set a different IP
address for each drive on the network.
F7-14: Duplex Mode Selection
No.
Name
(Hex.)
F7-14
Duplex Mode Selection
(03F2)
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
Port 1 is set to "Half" and port 2 is set to "Auto".
4 : Half/Full
Port 1 is set to "Half" and port 2 is set to "Full".
5 : Auto/Half
Port 1 is set to "Auto" and port 2 is set to "Half".
6 : Auto/Full
Port 1 is set to "Auto" and port 2 is set to "Full".
7 : Full/Half
Port 1 is set to "Full" and port 2 is set to "Half".
8 : Full/Auto
Port 1 is set to "Full" and port 2 is set to "Auto".
F7-15: Communication Speed Selection
No.
Name
(Hex.)
F7-15
Communication Speed
Selection
(03F3)
352
V/f
CL-V/f
OLV
CLV
AOLV
Sets the fourth octet of the gateway address of the connected network.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the method to set option card IP addresses.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the duplex mode setting method.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the communications speed.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
(Range)
1
(0 - 255)
Default
(Range)
2
(0 - 2)
Default
(Range)
1
(0 - 8)
Default
(Range)
10
(10, 100 - 102)