YASKAWA GA800 Programming Manual page 264

Ac drive for industrial applications
Table of Contents

Advertisement

2.4 C: Tuning
If C5-12 = 1 or C5-32 = 1 [Enabled] in Closed Loop V/f
Control, over/undershoot occurs when you change speeds.
Oscillation at low speed and response is too slow at high
speed.
Oscillation at high speed and response is too slow at low
speed.
C5-01: ASR Proportional Gain 1
No.
Name
(Hex.)
C5-01
ASR Proportional Gain 1
(021B)
RUN
A higher gain provides a higher speed response. Usually, the gain increases with larger loads. Too much gain will
cause vibration.
Note:
• The drive usually sets Motor 1 ASR with C5-01 and C5-02 [ASR Integral Time 1]. You can switch between C5-01 and C5-03 [ASR
Proportional Gain 2] by setting H1-xx = 77 [MFDI Function Selection = ASR Gain (C5-03) Select]. You can also use C5-01 and C5-02 as
alternatives to C5-03 and C5-04, respectively, when the speed is less than or equal to the frequency set in C5-07 [ASR Gain Switchover
Frequency].
• The drive automatically adjusts C5-01 in ASR Tuning.
C5-02: ASR Integral Time 1
No.
Name
(Hex.)
C5-02
ASR Integral Time 1
(021C)
RUN
When you increase the integral time, the responsiveness will decrease. An integral time that is too short can cause
oscillation.
C5-03: ASR Proportional Gain 2
No.
Name
(Hex.)
C5-03
ASR Proportional Gain 2
(021D)
RUN
A higher gain provides a higher speed response. Usually, the gain increases with larger loads. Too much gain will
cause vibration.
C5-04: ASR Integral Time 2
No.
Name
(Hex.)
C5-04
ASR Integral Time 2
(021E)
RUN
When you increase the integral time, the responsiveness will decrease. An integral time that is too short can cause
oscillation.
264
Problem
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain to adjust ASR response.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ASR integral time.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain to adjust ASR response.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ASR integral time.
• Decrease C5-01/C5-03.
• Increase C5-02/C5-04.
-
• Decrease the value set to C5-05.
• Closed Loop V/f Control Mode:
Use C5-03 and C5-04 at maximum speed and C5-01 and
C5-02 at minimum speed to set different ASR settings.
• Closed Loop Vector Control, PM Advanced Open Loop
-
Vector Control, and PM Closed Loop Vector Control:
Use C5-01 to C5-04 to set the best ASR settings for high
and low speed. Use C5-07 [ASR Gain Switchover
Frequency] to switch the ASR proportional gain and
ASR integral time as specified by the output frequency.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Possible Solutions
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Default
(Range)
Determined by A1-02
(0.000 - 60.000 s)
Default
(Range)
Determined by A1-02
(0.00 - 300.00)
Default
(Range)
Determined by A1-02
(0.000 - 60.000 s)