Set Sinking Mode/Sourcing Mode

Close the circuit between terminals SC-SP and SC-SN to set the sinking mode/sourcing mode and the internal/
external power supply for the MFDI terminals. The default setting for the drive is internal power supply sinking
mode.
NOTICE: Do not close the circuit between terminals SP and SN. A closed circuit between these terminals will cause damage to the
drive.
Mode
Sinking Mode (NPN)
Sourcing Mode
(PNP)

Set Input Signals for MFAI Terminals A1 to A3

Use terminals A1 to A3 to input a voltage or a current signal. Set the signal type as shown in
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Internal Power Supply (Terminal SN-SP)
Figure 4.30 Location of DIP Switch S1
4.6 Control I/O Connections
External 24 V power supply
Table
4.11.
4
633