YASKAWA GA800 Programming Manual page 501

Ac drive for industrial applications
Table of Contents

Advertisement

n8-15: Polarity Compensation Gain 4
No.
Name
(Hex.)
n8-15
Polarity Compensation Gain
4
(054E)
Expert
n8-21: Motor Back-EMF (Ke) Gain
No.
Name
(Hex.)
n8-21
Motor Back-EMF (Ke) Gain
(0554)
Expert
n8-23: ACR q Gain @PoleEst
No.
Name
(Hex.)
n8-23
ACR q Gain @PoleEst
(0556)
Expert
n8-24: ACR q Integral Time @PoleEst
No.
Name
(Hex.)
n8-24
ACR q Integral Time
@PoleEst
(0557)
Expert
n8-25: ACR q Limit @PoleEst
No.
Name
(Hex.)
n8-25
ACR q Limit @PoleEst
(0558)
Expert
n8-26: ACR d Gain @PoleEst
No.
Name
(Hex.)
n8-26
ACR d Gain @PoleEst
(0559)
Expert
n8-27: ACR d Integral Time @PoleEst
No.
Name
(Hex.)
n8-27
ACR d Integral Time
@PoleEst
(055A)
Expert
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain for current regulator q-axis control when the drive estimates the initial
pole. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time for current regulator q-axis control when the drive estimates the initial pole.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the q-axis limit of the current regulator when the drive estimates the initial pole. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain for current regulator d-axis control when the drive estimates the initial
pole. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time for current regulator d-axis control when the drive estimates the initial pole.
Usually it is not necessary to change this setting.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.10 n: Special Adjustment
Default
(Range)
0.500
(0.000 - 10.000)
Default
(Range)
0.90
(0.80 - 1.00)
Default
(Range)
0
(0 - 2000)
Default
(Range)
0.0 ms
(0.0 - 100.0 ms)
Default
(Range)
0%
(0 - 150%)
Default
(Range)
500
(0 - 2000)
Default
(Range)
0.0 ms
(0.0 - 100.0 ms)
2
501