L9: Drive Protection 2 - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

This function detects when PM motors are not synchronized.
The drive cannot detect when motors are not synchronized because the frequency reference is low during start up and
the motor is locked. If fault detection is necessary in these conditions, set the control fault detection level to enable
detection of desynchronization because of motor locking. Increase the setting in 5-unit increments.
L8-93: Low Speed Pull-out DetectionTime
No.
Name
(Hex.)
L8-93
Low Speed Pull-out
DetectionTime
(073C)
Expert
Set this parameter to 0.0 to disable the function.
L8-94: Low Speed Pull-out Detect Level
No.
Name
(Hex.)
L8-94
Low Speed Pull-out Detect
Level
(073D)
Expert
L8-95: Low Speed Pull-out Amount
No.
Name
(Hex.)
L8-95
Low Speed Pull-out Amount
(077F)
Expert

L9: Drive Protection 2

L9 parameters are used to configure the protection function used to detect cooling fan faults.
L9-16: FAn1 Detect Time
No.
Name
(Hex.)
L9-16
FAn1 Detect Time
(11DC)
Expert
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time the drive will wait to start baseblock after detecting LSo [Low Speed Motor
Step-Out].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level for LSo [Low Speed Motor Step-Out] as a percentage of E1-04 [Maximum
Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the average count of LSo [Low Speed Motor Step-Out] detections.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for FAn1 [Drive Cooling Fan Fault]. Yaskawa recommends that you do not
change this parameter value.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.9 L: Protection Functions
Default
(Range)
1.0 s
(0.0 - 10.0 s)
Default
(Range)
3%
(0 - 10%)
Default
(Range)
10
(1 - 50 times)
Default
(Range)
4.0 s
(0.0 - 30.0 s)
2
483

Advertisement

Table of Contents
loading

Table of Contents