1.12 n: Special Adjustment
No.
Name
(Hex.)
n8-51
Pull-in Current @
Acceleration
(053E)
n8-52
ACR P Gain
(053F)
Expert
n8-54
Voltage Error
Compensation Time
(056D)
Expert
n8-55
Motor to Load Inertia
Ratio
(056E)
n8-56
PM High Performance
Selection
(056F)
Expert
n8-57
HFI Overlap Selection
(0574)
n8-62
Output Voltage Limit
Level
(057D)
Expert
n8-63
Output Voltage Limit P
Gain
(057E)
Expert
n8-64
Output Voltage Limit I
Time
(057F)
Expert
n8-65
Speed Fdbk Gain @ oV
Suppression
(065C)
Expert
n8-66
Output Voltage Limit
Filter Time
(0235)
Expert
n8-69
Speed Observer Control P
Gain
(065D)
Expert
n8-70
Speed Observer Control I
Time
(065E)
Expert
n8-71
Speed Observer Control
D Gain
(065F)
Expert
98
V/f
CL-V/f
OLV
CLV
AOLV
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage of
the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor
rated current.
• A1-02 = 5 [OLV/PM]: E5-03 [Motor Rated Current (FLA)]
• A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain of the current regulator. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that the drive uses when adjusting for voltage errors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between motor inertia and machine inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
V/f
CL-V/f
OLV
CLV
AOLV
Sets the high efficiency control method for IPM motor. Usually it is not necessary to
change this setting.
0 : Disabled
1 : Enabled (Vd)
2 : Enabled (Vd & Vq)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that detects motor speed with high frequency injection.
Note:
When you set n8-57 = 1, doHigh Frequency Injection Auto-Tuning.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not
necessary to change this parameter.
Note:
• When A1-02 = 7, 8 [Control Method Selection = CLV/PM, EZOLV], this parameter
is available in Expert Mode.
• When A1-02 = 8, the default setting is
–200 V Class: 230.0 V
–400 V Class: 460.0 V
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain for output voltage control. Usually it is not necessary to change
this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time for output voltage control. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of internal speed feedback detection suppression while the overvoltage
suppression function is operating as a magnification value. Usually it is not necessary to
change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant for output voltage control. Usually it is not necessary to change
this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain that the drive uses for speed estimation. Usually it is not necessary to change
this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed estimator integral time constant. It is available when n8-72 = 1 [Speed
Estimation Method Select = Method 2]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Set the speed estimator differential gain. It is available when n8-72 = 1 [Speed Estimation
Method Select = Method 2]. Usually it is not necessary to change this setting.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
Ref.
(Range)
Determined by A1-02
504
(0 - 200%)
10.0
505
(-100.0 - 100.0)
1.00 s
505
(0.00 - 10.00 s)
0
505
(0 - 3)
1
506
(0 - 2)
0
506
(0, 1)
200 V Class: 200.0 V, 400
506
V Class: 400.0 V
(200 V Class: 0.0 to 240.0
V, 400 V Class: 0.0 to
480.0 V)
1.00
506
(0.00 - 100.00)
0.040 s
507
(0.000 - 5.000 s)
1.50
507
(0.00 - 10.00)
0.020 s
507
(0.000 - 5.000 s)
1.00
507
(0.00 - 20.00)
0.0 s
507
(0.0 - 100.0 s)
5.00
507
(0.00 - 50.00)