E5-01: PM Motor Code Selection
No.
Name
(Hex.)
E5-01
PM Motor Code Selection
(0329)
Note:
• If the drive hunts or shows an alarm after you use a motor code, use the keypad to enter the value shown on the nameplate to E5-xx.
• When you use a PM motor other than a Yaskawa SMRA, SSR1, or SST4 series, set E5-01 = FFFF.
Figure 2.73
gives information about the motor code setting digits.
E5-02: PM Motor Rated Power
No.
Name
(Hex.)
E5-02
PM Motor Rated Power
(032A)
The drive will automatically set this parameter the next time you do Auto-Tuning.
• PM Motor Parameter Settings
• PM Stationary Auto-Tuning
• PM Rotational Auto-Tuning
E5-03: PM Motor Rated Current (FLA)
No.
Name
(Hex.)
E5-03
PM Motor Rated Current
(FLA)
(032B)
Note:
When the drive model changes, the display units for this parameter also change.
• 0.01 A: models 2004 to 2042, 4002 to 4023
• 0.1 A: models 2056 to 2415, 4031 to 4720
After you do these types of Auto-Tuning, the drive automatically will set E5-03 to the value input for "PM Motor
Rated Current":
• PM Motor Parameter Settings
• PM Stationary Auto-Tuning
• PM StaTun for Stator Resistance
• PM Rotational Auto-Tuning
E5-04: PM Motor Pole Count
No.
Name
(Hex.)
E5-04
PM Motor Pole Count
(032C)
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor code for Yaskawa PM motors. The drive uses the motor code to set some parameters
to their correct settings automatically.
Figure 2.73 PM Motor Code
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor rated output in the units set in o1-58 [Motor Power Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor rated current (FLA).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PM motor poles.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.6 E: Motor Parameters
Default
(Range)
FFFF
(0000 - FFFF)
Default
(Range)
Determined by o2-04, C6-01
(0.10 - 650.00 HP)
Default
(Range)
Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
Default
(Range)
4
(2 - 120)