2.8 H: Terminal Functions
Drives have three analog input terminals, terminals A1, A2, and A3. H3 parameters select the functions set to these
analog input terminals and adjust signal levels.
Table 2.64
shows the functions that you can set to analog input terminals. Use H3-02, H3-06, and H3-10 [MFAI
Function Selection] to set functions.
Setting
Function
Value
0
Frequency Reference
1
Frequency Gain
2
Auxiliary Frequency Reference 1
3
Auxiliary Frequency Reference 2
4
Output Voltage Bias
5
Accel/Decel Time Gain
6
DC Injection Braking Current
7
Torque Detection Level
8
Stall Prevent Level During Run
9
Output Frequency Lower Limit
B
PID Feedback
C
PID Setpoint
D
Frequency Bias
Note:
All analog input scaling uses gain and bias for adjustment. Set the gain and bias values correctly.
406
Table 2.64 MFAI Setting Values
Setting
Ref.
Value
413
E
Motor Temperature (PTC Input)
413
F
Not Used
413
10
Forward Torque Limit
414
11
Reverse Torque Limit
414
12
Regenerative Torque Limit
13
Torque Reference / Torque Limit
414
414
14
Torque Compensation
415
15
General Torque Limit
415
16
Differential PID Feedback
415
1F
Not Used
415
30
DWEZ Analog Input 1
416
31
DWEZ Analog Input 2
416
32
DWEZ Analog Input 3
Function
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Ref.
416
416
416
417
418
418
418
418
418
418
418
418
419

Advertisement

Table of Contents
loading