YASKAWA GA800 Programming Manual page 519

Ac drive for industrial applications
Table of Contents

Advertisement

2 : Clear all
Deletes all of the saved user parameter setting values.
Set o2-03 = 2 then push
you delete the user parameter setting values, you cannot set A1-03 = 1110 to initialize parameters.
o2-04: Drive Model (KVA) Selection
No.
Name
(Hex.)
o2-04
Drive Model (KVA)
Selection
(0508)
NOTICE: Set o2-04 [Drive Model Selection] correctly. If you set this parameter incorrectly, it will decrease drive performance, cause
the protection function to operate incorrectly, and cause damage to the drive.
Note:
When the setting value of o2-04 changes, related parameter setting values also change. Refer to
ND/HD on page 133
for more information.
These tables list the relation between o2-04 setting values and drive models.
o2-04 Setting
62
63
64
65
66
67
68
6A
6B
6D
6E
6F
70
72
73
74
75
76
77
78
92
93
94
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
to clear the user parameter setting values. The drive will automatically reset o2-03 to 0. If
V/f
CL-V/f
OLV
CLV
Sets the Drive Model code. Set this parameter after replacing the control board.
Drive Model
2004
2006
2008
2010
2012
2018
2021
2030
2042
2056
2070
2082
2110
2138
2169
2211
2257
2313
2360
2415
4002
4004
4005
2.11 o: Keypad-Related Settings
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Defaults by Drive Model and Duty Rating
o2-04 Setting
95
96
97
99
9A
9C
9D
9E
9F
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AC
AD
AE
AF
Default
(Range)
Determined by the drive
(-)
Drive Model
4007
4009
4012
4018
4023
4031
4038
4044
4060
4075
4089
4103
4140
4168
4208
4250
4302
4371
4414
4477
4568
4605
4720
2
519

Advertisement

Table of Contents
loading