YASKAWA GA800 Programming Manual page 401

Ac drive for industrial applications
Table of Contents

Advertisement

33: Zero Servo Complete
Setting Value
Function
33
Zero Servo Complete
Note:
Refer to "b9: Zero Servo" for more information.
37: During Frequency Output
Setting Value
Function
37
During Frequency Output
ON : The drive outputs frequency.
OFF : The drive does not output frequency.
Note:
The terminal deactivates in these conditions:
• During Stop
• During baseblock
• During DC Injection Braking (initial excitation)
• During Short Circuit Braking
38: Drive Enabled
Setting Value
Function
38
Drive Enabled
39: Watt Hour Pulse Output
Setting Value
Function
39
Watt Hour Pulse Output
Note:
Refer to "H2-06: Watt Hour Output Unit Selection" for more information.
3C: LOCAL Control Selected
Setting Value
Function
3C
LOCAL Control Selected
ON : LOCAL
The keypad is the Run command source or the frequency reference source.
OFF : REMOTE
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when positioning in the range set with b9-02 [Zero Servo Completion Window] completes after sending the
Zero-Servo command.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive outputs frequency.
Figure 2.100 Active Frequency Output Time Chart
V/f
CL-V/f
OLV
CLV
AOLV
This terminal activates when the H1-xx = 6A [Drive Enable] terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Outputs the pulse that shows the watt hours.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the Run command source or frequency reference source is LOCAL.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
2.8 H: Terminal Functions