1.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
No.
Name
b6-03
Dwell Reference at Stop 0.0 - 400.0
b8-02
Energy Saving Gain
Energy Saving Filter
b8-03
Time
E-Save Search Injection
b8-19
Freq
Accel/Decel Time
C1-11
Switchover Freq
S-Curve Time @ Start
C2-01
of Accel
C3-01
Slip Compensation Gain 0.0 - 2.5
Slip Compensation
C3-02
Delay Time
Torque Compensation
C4-01
Gain
Torque Compensation
C4-02
Delay Time
ASR Proportional Gain
C5-01
1
C5-02
ASR Integral Time 1
ASR Proportional Gain
C5-03
2
C5-04
ASR Integral Time 2
C5-06
ASR Delay Time
ASR Gain Switchover
C5-07
Frequency
Carrier Frequency
C6-02
Selection
d3-01
Jump Frequency 1
d3-02
Jump Frequency 2
d3-03
Jump Frequency 3
d3-04
Jump Frequency Width
Torque Reference Delay
d5-02
Time
Maximum Output
E1-04
Frequency
Maximum Output
E1-05
Voltage
E1-06
Base Frequency
E1-07
Mid Point A Frequency 0.0 - 400.0
E1-08
Mid Point A Voltage
Minimum Output
E1-09
Frequency
Minimum Output
E1-10
Voltage
Encoder 1 Pulse Count
F1-01
(PPR)
Encoder 1 Rotation
F1-05
Selection
Overspeed Detection
F1-09
Delay Time
Motor Overload (oL1)
L1-01
Protection
128
Range
Unit
*3
0.1
0.0 - 10.0
0.1
0.00 - 10.00
0.01 s
10 - 300
1 Hz
*3
0.0 - 400.0
0.1
0.00 - 10.00
0.01 s
0.1
0 - 10000
1 ms
0.00 - 2.50
0.01
0 - 60000
1 ms
0.00 - 300.00
0.01
0.000 - 60.000
0.001 s
0.00 - 300.00
0.01
0.000 - 60.000
0.001 s
0.000 - 0.500
0.001 s
*3
0.0 - 400.0
0.1
1 - F
1
*3
0.0 - 400.0
0.1
*3
0.0 - 400.0
0.1
*3
0.0 - 400.0
0.1
*4
0.0 - 20.0
0.1
0 - 1000
1 ms
*5
40.0 - 400.0
0.1 Hz
*6
0.0 - 255.0
0.1 V
0.0 - 400.0
0.1 Hz
0.1 Hz
*6
0.0 - 255.0
0.1 V
0.0 - 400.0
0.1 Hz
*6
0.0 - 255.0
0.1 V
0 - 60000
1 ppr
0 - 1
1
0.0 - 2.0
0.1 s
0 - 6
1
Control Method (A1-02 Setting)
OLV/PM
AOLV/PM
(5)
(6)
0.0 Hz
0.0%
-
-
-
-
-
100
0.0 Hz
0.0%
1.00
0.20
-
-
-
-
0.00
-
100
-
-
10.00
-
0.500
-
10.00
-
0.500
-
0.016
-
0.0%
2
2
0.0 Hz
0.0%
0.0 Hz
0.0%
0.0 Hz
0.0%
1.0 Hz
1.0%
-
0
Determined by E5-01 Determined by E5-01 Determined by E5-01
Determined by E5-01 Determined by E5-01 Determined by E5-01
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
-
-
-
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
-
-
-
-
-
-
0.0
4
4
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
CLV/PM
EZOLV
(7)
(8)
0.0%
0.0 Hz
-
-
-
-
100
20
0.0%
0.0 Hz
0.20
1.00
-
0.0
-
200
-
0.00
-
200
20.00
10.00
0.500
0.500
20.00
10.00
0.500
0.500
0.004
0.004
0.0%
0.0 Hz
2
2
0.0%
0.0 Hz
0.0%
0.0 Hz
0.0%
0.0 Hz
1.0%
1.0 Hz
0
-
-
-
-
-
-
-
-
-
-
-
1024
-
1
-
0.0
0.0
5
1

Advertisement