YASKAWA GA800 Programming Manual page 322

Ac drive for industrial applications
Table of Contents

Advertisement

2.7 F: Options
F1-33: Encoder 2 Gear Teeth 1
No.
Name
(Hex.)
F1-33
Encoder 2 Gear Teeth 1
(03B2)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When F1-33 = 0 or F1-34 = 0, the gear ratio is 1.
F1-34: Encoder 2 Gear Teeth 2
No.
Name
(Hex.)
F1-34
Encoder 2 Gear Teeth 2
(03B3)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When F1-33 = 0 or F1-34 = 0, the gear ratio is 1.
F1-35: Encoder 2 Pulse Monitor Scaling
No.
Name
(Hex.)
F1-35
Encoder 2 Pulse Monitor
Scaling
(03BE)
When the setting value is a 3-digit value (xyz), the dividing ratio is (1 + x)/yz.
For example, when F1-35 = 032, the dividing ratio is 1/32.
Note:
For a single-pulse encoder, the dividing ratio for the monitor signal is 1:1.
F1-36: Encoder 2 PCB Disconnect Detect
No.
Name
(Hex.)
F1-36
Encoder 2 PCB Disconnect
Detect
(03B5)
0 : Disabled
1 : Enabled
F1-37: Encoder 2 Signal Selection
No.
Name
(Hex.)
F1-37
Encoder 2 Signal Selection
(03BD)
0 : A Pulse Detection
1 : AB Pulse Detection
322
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the motor side for motor 2. This parameter and F1-34 [Encoder 2
Gear Teeth 2] set the gear ratio between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the load side for motor 2. This parameter and F1-33 [Encoder 2
Gear Teeth 1] set the gear ratio between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between the pulse input and the pulse output of the encoder as a 3-digit number for
motor 2. The first digit is the numerator and the second and third digits set the denominator.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enables and disables detection of a disconnected encoder connection cable to
cause PGoH [Encoder (PG) Hardware Fault] for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of channels for the signal to the encoder option card for motor 2.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
(Range)
0
(0 - 1000)
Default
(Range)
0
(0 - 1000)
Default
(Range)
001
(001 - 032, 102 - 132 (1 - 1/
32))
Default
(Range)
1
(0, 1)
Default
(Range)
0
(0, 1)