YASKAWA GA800 Programming Manual page 399

Ac drive for industrial applications
Table of Contents

Advertisement

OFF : During baseblock
1C: Motor 2 Selected
Setting Value
Function
1C
Motor 2 Selected
ON : Motor 2 Selection
OFF : Motor 1 Selection
1D: During Regeneration
Setting Value
Function
1D
During Regeneration
ON : Motor is regenerating.
OFF : Motor is operating or stopped.
1E: Executing Auto-Restart
Setting Value
Function
1E
Executing Auto-Restart
The terminal deactivates when the Auto Restart function automatically resets a fault. The terminal turns off when the
Auto Restart function detects the fault again since Auto Restart function cannot function any longer due to number of
attempts set with L5-01 [Number of Auto Restart Attempts] being reached.
Note:
Refer to "L5: Auto-Restart" for more information.
1F: Motor Overload Alarm (oL1)
Setting Value
Function
1F
Motor Overload Alarm
(oL1)
Note:
Refer to "L1-01: Motor Overload (oL1) Protection" for more information.
20: Drive Overheat Pre-Alarm (oH)
Setting Value
Function
20
Drive Overheat Pre-Alarm
(oH)
Note:
Refer to "L8-02: Overheat Alarm Level" for more information.
21: Safe Torque OFF
Setting Value
Function
21
Safe Torque OFF
Note:
EDM = External Device Monitor
ON : Safety stop state
Terminals H1-HC and H2-HC are OFF (Open) (safety stop state).
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when motor 2 is selected.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates on when the motor is regenerating.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the Auto Restart function is trying to restart after a fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the electronic thermal protection value of the motor overload protective function is a minimum of 90%
of the detection level.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive heatsink temperature is at the level set with L8-02 [Overheat Alarm Level].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates (safety stop state) when the safety circuit and safety diagnosis circuit are operating correctly and when
terminals H1-HC and H2-HC are OFF (Open).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
2.8 H: Terminal Functions