YASKAWA GA800 Programming Manual page 354

Ac drive for industrial applications
Table of Contents

Advertisement

2.7 F: Options
F7-23 to F7-32: Dynamic Out Param 1 to 10 for CommCard
No.
Name
(Hex.)
F7-23 - F7-27
Dynamic Out Param 1 to 10
for CommCard
(03FB - 03FF)
F7-28- F7-32
(0370 - 0374)
F7-33 to F7-42: Dynamic In Param 1 to 10 for CommCard
No.
Name
(Hex.)
F7-33 - F7-42
Dynamic In Param 1 to 10
for CommCard
(0375 - 037E)
F7-60: PZD1 Write (Control Word)
No.
Name
(Hex.)
F7-60
PZD1 Write (Control Word)
(0780)
F7-61: PZD2 Write (Frequency Reference)
No.
Name
(Hex.)
F7-61
PZD2 Write (Frequency
Reference)
(0781)
F7-62: PZD3 Write
No.
Name
(Hex.)
F7-62
PZD3 Write
(0782)
F7-63: PZD4 Write
No.
Name
(Hex.)
F7-63
PZD4 Write
(0783)
F7-64: PZD5 Write
No.
Name
(Hex.)
F7-64
PZD5 Write
(0784)
354
V/f
CL-V/f
OLV
CLV
AOLV
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to the
MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write the
values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166. The drive sends the values from the MEMOBUS/Modbus address registers
stored for each parameter to Input Assembly 166. The drive returns the default register value for the
option card when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO output) functions as the
STW when F7-60 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO output). PZD2 (PPO output) functions as the
HSW when F7-61 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will disable the
PZD3 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD4 (PPO output). A value of 0, 1, or 2 will disable the
PZD4 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD5 (PPO output). A value of 0, 1, or 2 will disable the
PZD5 (PPO output) write operation to the MEMOBUS/Modbus register.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0