1.10 H: Terminal Functions
No.
Name
(Hex.)
H2-36
Comparator 1 Ineffective
Time
(159E)
H2-37
Comparator 2 Ineffective
Time
(159F)
H2-40
Mbus Reg 15E0h bit0
Output Func
(0B58)
H2-41
Mbus Reg 15E0h bit1
Output Func
(0B59)
H2-42
Mbus Reg 15E0h bit2
Output Func
(0B5A)
H2-60
Term M1-M2 Secondary
Function
(1B46)
Expert
H2-61
Terminal M1-M2 Logical
Operation
(1B47)
Expert
Terminal M1-M2 Delay
H2-62
Time
(1B48)
Expert
H2-63
Term M3-M4 Secondary
Function
(1B49)
Expert
H2-64
Terminal M3-M4 Logical
Operation
(1B4A)
Expert
H2-65
Terminal M3-M4 Delay
Time
(1B4B)
Expert
H2-66
Term M5-M6 Secondary
Function
(1B4C)
Expert
H2-67
Terminal M5-M6 Logical
Operation
(1B4D)
Expert
H2-68
Terminal M5-M6 Delay
Time
(1B4E)
Expert
68
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that CP1 [Comparator1 Limit Fault] is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that CP2 [Comparator2 Limit Fault] is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for terminal M1-M2. Outputs the logical calculation results of the
terminals assigned to functions by H2-01 [Term M1-M2 Function Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the logical operation for the functions set in H2-01 [Term M1-M2 Function Selection]
and H2-60 [Term M1-M2 Secondary Function].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum on time used to output the logical calculation results from terminal M1-
M2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for terminal M3-M4. Outputs the logical calculation results of the
terminals assigned to functions by H2-02 [Term M3-M4 Function Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the logical operation for the functions set in H2-02 [Term M3-M4 Function Selection]
and H2-63 [Term M3-M4 Secondary Function].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum on time used to output the logical calculation results from terminal M3-
M4.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the second function for terminal M5-M6. Outputs the logical calculation results of the
terminals assigned to functions by H2-03 [Terminal M5-M6 Function Select].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the logical operation for the functions set in H2-03 [Term M5-M6 Function Selection]
and H2-66 [Term M5-M6 Secondary Function].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum on time used to output the logical calculation results from terminal M5-
M6.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
Ref.
(Range)
0.0 s
388
(0.0 - 1000.0 s)
0.0 s
388
(0.0 - 1000.0 s)
F
388
(0 - 1FF)
F
388
(0 - 1FF)
F
388
(0 - 1FF)
F
389
(0 - FF)
0
389
(0 - 8)
0.1 s
389
(0.0 - 25.0 s)
F
389
(0 - FF)
0
389
(0 - 8)
0.1 s
389
(0.0 - 25.0 s)
F
389
(0 - FF)
0
390
(0 - 8)
0.1 s
390
(0.0 - 25.0 s)

Advertisement