6-2-28 ENGINE GENERAL INFORMATION AND DIAGNOSIS (J18 ENGINE WITH WU TWC)
SCAN TOOL DATA
DESIRED IDLE
(DESIRED IDLE
(DESIRED IDLE
SPEED)
TP SENSOR VOLT
(
(THROTTLE POSITION
SENSOR OUTPUT
VOLTAGE)
INJ PULSE WID (FUEL
INJECTION PULSE
INJECTION PULSE
WIDTH)
IAC FLOW DUTY (IDLE
AIR CONTROL FLOW
DUTY)
TOTAL FT
BATTERY VOLTAGE
CANIST PRG DUTY
(EVAP CANISTER
PURGE FLOW DUTY)
CLOSED THROT POS
(CLOSED THROTTLE
(CLOSED THROTTLE
POSITION)
FUEL CUT
FUEL CUT
ELECTRIC LOAD
ELECTRIC LOAD
A/ C SWITCH
A/ C SWITCH
PSP SWITCH
(POWER STEERING
(
PRESSURE SWITCH)
(if equipped)
RADIATOR FAN
(RADIATOR FAN
(RADIATOR FAN
CONTROL RELAY)
A/C CONDENSER FAN
A/C CONDENSER FAN
BLOWER FAN
BLOWER FAN
FUEL PUMP
U
U
EGR VALVE
FUEL TANK LEVEL
CONDITION
At idling with no load after warming up, M/T at neutral,
d g
o oad a e
A/T at "P" range
Accelerator pedal released
Ignition switch
ON/ warm engine
ON/ warm engine
stopped
Accelerator pedal depressed fully
At specified idle speed with no load after warming up
At 2500 r / min. with no load after warming up
At idling with no load after warming up
At specified idle speed after warming up
Ignition switch ON / engine stop
At specified idle speed after warming up
Throttle valve at idle position
Throttle valve opens larger than idle position
When engine is at fuel cut condition
Other than fuel cut condition
Ignition switch ON / Headlight, small light and rear
window defogger all turned OFF
Ignition switch ON / Headlight, small light or rear
window defogger turned ON
Engine running after warming up, A / C not operating
Engine running after warming up, A / C operating
Engine running at idle speed and steering wheel at
straight-ahead position
Engine running at idle speed and steering wheel
turned to the right or left as far as it stops
Engine coolant temp.:
Lower than 93_C (200_F)
Ignition switch ON
Ignition switch ON
Engine coolant temp.:
A/C switch ON
Ignition switch ON
Ignition switch ON
A/C switch OFF
Blower fan switch ON
Ignition switch ON
Ignition switch ON
Blower fan switch OFF
Within 3 seconds after ignition switch ON or engine
running
Engine stop at ignition switch ON.
At specified idle speed after warming up
––––––––––––
a
g u ,
/ a
eu a ,
98_C (208_F) or higher
NORMAL CONDITION /
REFERENCE VALUES
750 r / min.
750 r / min
0.35 – 0.65 V
3.5 – 4.5 V
1.8 – 3.0 msec.
1.8 – 3.0 msec.
35 – 45%
– 33 – +33%
10 – 14 V
0 %
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
0%
0 – 100%