1D-60 Engine Mechanical:
Air Cleaner Assembly Replacement
Removal Procedure
1. Remove the air cleaner outlet duct. Refer to "Air
Cleaner Outlet Duct Replacement".
2. Disconnect the engine wiring harness electrical
connector from the mass air flow (MAF)/intake air
temperature (IAT) sensor.
3. Remove the air cleaner bolt.
4. Disengage the air cleaner pins from the front panel
and remove the air cleaner assembly.
5. If replacing the air cleaner assembly, remove the
MAF/IAT sensor. Refer to "Mass Airflow Sensor/
Intake Air Temperature Sensor Replacement: ".
Installation Procedure
1. If the air cleaner assembly was replaced, install the
MAF/IAT sensor. Refer to "Mass Airflow Sensor/
Intake Air Temperature Sensor Replacement: ".
2. Install the air cleaner assembly by inserting the two
pins into the front panel.
CAUTION
!
Refer to "Fastener Notice: ".
3. Install the air cleaner bolt.
Tightening torque
Tighten the bolt to 10 N⋅m (89 lb in).
4. Connect the engine wiring harness electrical
connector to the MAF/IAT sensor.
5. Install the air cleaner outlet duct. Refer to "Air
Cleaner Outlet Duct Replacement".