Suzuki XL7 2007 Service Manual page 331

Jc636
Hide thumbs Also See for XL7 2007:
Table of Contents

Advertisement

Camshaft Position Actuator Solenoid Valve
Solenoid Replacement - Bank 1 (Right Side)
Intake
Removal Procedure
1. Remove the air cleaner assembly. Refer to "Air
Cleaner Assembly Replacement: ".
2. Disconnect the engine wiring harness electrical
connector (3) from the bank 1 intake camshaft
position (CMP) actuator solenoid valve.
3. Remove the CMP actuator solenoid valve bolt.
4. Remove the CMP actuator solenoid valve.
5. Inspect the CMP actuator solenoid valve seal and
replace as necessary.
Engine Electrical Devices:
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for
damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
CAUTION
!
Refer to "Fastener Notice: ".
3. Install the CMP actuator solenoid valve bolt.
Tightening torque
Tighten the bolt to 10 N⋅m (89 lb in).
4. Connect the engine wiring harness electrical
connector (3) to the bank 1 intake CMP actuator
solenoid valve.
5. Install the air cleaner assembly. Refer to "Air Cleaner
Assembly Replacement: ".
1C-25