Download  Print this page

Monitor Item Selection On Operation Panel Or Via Communication - Mitsubishi Electric FR-F820-00046 Instruction Manual

Fr-f800 series.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660

Advertisement

Parameters referred to
Pr.1 Maximum
frequencypage 271
Pr.52 Operation panel main monitor
Pr.81 Number of motor
polespage 169
Pr.800 Control method
selectionpage 169
5.8.2
Monitor item selection on operation panel or via
communication
The monitor item to be displayed on the operation panel or the parameter unit can be selected.
Pr.
Name
52
Operation panel main
M100
monitor selection
774
Operation panel monitor
M101
selection 1
775
Operation panel monitor
M102
selection 2
776
Operation panel monitor
M103
selection 3
992
Operation panel setting dial
M104
push monitor selection
170
Watt-hour meter clear
M020
563
Energization time carrying-
M021
over times
268
Monitor decimal digits
M022
selection
891
Cumulative power monitor
M023
digit shifted times
171
Operation hour meter clear 9999
M030
564
Operating time carrying-
M031
over times
290
Monitor negative output
M044
selection
1018
Monitor with sign selection 9999
M045
1106
Torque monitor filter
M050
1107
Running speed monitor
M051
filter
1108
Excitation current monitor
M052
filter
288
5. PARAMETERS
5.8 (M) Item and output signal for monitoring
selectionpage 288
Initial value
Setting range
0, 5 to 14, 17, 18,
20, 23 to 25, 34, 38,
0 (output
40 to 45, 50 to 57,
frequency)
61, 62, 64, 67 to 69,
81 to 96, 98, 100
1 to 3, 5 to 14, 17,
18, 20, 23 to 25, 34,
38, 40 to 45, 50 to
9999
57, 61, 62, 64, 67 to
69, 81 to 96, 98,
100, 9999
0 to 3, 5 to 14, 17,
18, 20, 23 to 25, 34,
0 (set
38, 40 to 45, 50 to
frequency)
57, 61, 62, 64, 67 to
69, 81 to 96, 98,
100
0
10
9999
9999
(0 to 65535)
0
(Read-only)
0
9999
1
9999
0 to 4
9999
9999
0
9999
(0 to 65535)
0
(Read-only)
0
0 to 7
0
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
Description
Select the item monitored on the operation panel or
parameter unit.
Refer to
page 289
for the monitor item selection.
Each of the initial items monitored on the operation panel or
parameter unit in the monitor mode (output frequency,
output current, and output voltage) can be switched to a
user-designated item.
9999: Follows the Pr.52 setting.
Select the monitor item displayed on the operation panel at
the time when the setting dial is pressed.
Set "0" to clear the watt-hour meter.
Set "10" to monitor the cumulative power in the range of 0 to
9999 kWh via communication.
Set "9999" to monitor the cumulative power in the range of 0
to 65535 kWh via communication.
The number of times that the cumulative energization time
exceeded 65535 hours is displayed (read-only).
Value is displayed in 1 increments (an integer).
Value is displayed in 0.1 increments.
No function
Set the number of digits to move the decimal point of the
cumulative energy monitored value to the left.
The readout peaks out at the upper limit of readout.
The function of moving the decimal point is not available.
The readout is reset to 0 when it exceeds the upper limit.
Set "0" to clear the operation hour meter.
The readout is always 9999. Nothing changes when "9999"
is set.
The number of times that the operating time reaches 65535
hours is displayed. Read-only.
Set the availability of negative signals output via terminal
AM, to the operation panel, and through communication.
Select the item group to enable the indication of negative
signed numbers.
The filter time constant is selectable for monitoring of the
torque. A larger setting results in slower response.
0.3 s filter
The filter time constant is selectable for monitoring of the
running speed. A larger setting results in slower response.
0.08 s filter
The filter time constant is selectable for monitoring of the
motor excitation current. A larger setting results in slower
response.
0.3 s filter

Advertisement

Table of Contents

   Related Content for Mitsubishi Electric FR-F820-00046

Comments to this Manuals

Symbols: 0
Latest comments: