Mitsubishi Electric FR-F820-00046 Instruction Manual page 171

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

• Start-time tuning start external input (X28) signal
 Output terminal function selection (Pr.190 to Pr.196)
• Electronic thermal O/L relay pre-alarm (THP) signal
• Start time tuning completion (Y39) signal
Parameters referred to
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
 Status of the monitoring during the test operation
○: Enabled
×: Disabled (0 is displayed at any time.)
∆: A cumulative total before the test operation is displayed.
—: Not available
Monitor item
Output frequency
Fault indication
Frequency setting value
Motor speed
Converter output voltage
Electronic thermal O/L relay load factor ×
Output current peak value
Converter output voltage peak value
Load meter
Cumulative energization time
Reference voltage output
Actual operation time
Cumulative energy
Trace status
Station number (RS-485 terminals)
Station number (PU connector)
Station number (CC-Link)
Energy saving effect
Cumulative energy saving
PID set point
PID measured value
*1
The monitoring-enabled items differ depending on the output interface (operation panel, parameter unit, terminal FM/CA, or terminal AM). For the
details, refer to
*2
When the inverter operation is switched to the test operation, the indication is changed to 0. When PM motor control is selected again after the
test operation, the output current peak value and the electronic thermal relay load factor from the last operation are displayed.
*3
The output is enabled via terminal AM only.
*4
When the inverter operation is switched to the test operation, the accumulated thermal value is reduced because the output current is considered
as 0.
Parameters referred to
Pr.52 Operation panel main monitor
Pr.158 AM terminal function
 Changing the control method with external terminals (RT signal, X18
signal)
• Control method (V/F control or Advanced magnetic flux vector control) can be switched using external terminals.
The control method can be switched using either the Second function selection (RT) signal or the V/F switchover (X18)
signal.
• When using the RT signal, set the second motor in Pr.450 Second applied motor. Turning ON the RT signal enables the
second function, enabling the switchover of the control method.
170
5. PARAMETERS
5.2 Control method
selection)page 355
selection)page 312
Output via
Monitoring
terminal
on DU/PU
FM/CA/AM
*2
*2
×
*2
*2
×
×
×
page
297.
selectionpage 288
selectionpage 297
Monitor item
PID deviation
Input terminal status
Output terminal status
Option input terminal status
Option output terminal status
Motor thermal load factor
Inverter thermal load factor
PTC thermistor value
PID measured value 2
PID input pressure value
Remote output 1
Remote output 2
Remote output 3
Remote output 4
PID manipulated variable
Second PID set point
Second PID measured value
Second PID deviation
Second PID measured value 2
Second PID manipulated variable
Output via
Monitoring
terminal
on DU/PU
FM/CA/AM
*3
*4
*4
*4
*4
*3
*3
*3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents