Input Terminal Function Selection - Mitsubishi Electric FR-F820-00046 Instruction Manual

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

5.9.8

Input terminal function selection

Use the following parameters to select or change the input terminal functions.
Pr.
Name
178
STF terminal
T700
function selection
179
STR terminal
T701
function selection
180
RL terminal function
T702
selection
181
RM terminal function
T703
selection
182
RH terminal function
T704
selection
183
RT terminal function
T705
selection
184
AU terminal function
T706
selection
185
JOG terminal
T707
function selection
186
CS terminal function
T708
selection
187
MRS terminal
T709
function selection
188
STOP terminal
T710
function selection
189
RES terminal
T711
function selection
Pr.
Name
699
Input terminal filter
T740
*1
The initial value is for standard models and IP55 compatible models.
*2
The initial value is for separated converter types.
 Input terminal function assignment
• Use Pr.178 to Pr.189 to set the functions of the input terminals.
• Refer to the following table and set the parameters.
Signal
Setting
name
Pr.59 = 0 (initial value)
0
RL
Pr.59 ≠ 0
Pr.59 = 0 (initial value)
1
RM
Pr.59 ≠ 0
Pr.59 = 0 (initial value)
2
RH
Pr.59 ≠ 0
3
RT
Second function selection
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
Selection of automatic restart after instantaneous power failure /
flying start
6
CS
Electronic bypass function
7
OH
External thermal relay input
Initial
Initial signal
value
60
STF (Forward rotation command)
61
STR (Reverse rotation command)
0
RL (Low-speed operation command)
1
RM (Middle-speed operation command)
2
RH (High-speed operation command)
3
RT (Second function selection)
4
AU (Terminal 4 input selection)
5
JOG (Jog operation selection)
9999
No function
*1
MRS (Output stop)
24
*2
X10 (Inverter run enable)
10
25
STP (STOP) (Start self-holding selection)
62
RES (Inverter reset)
Initial
Setting range
value
5 to 50 ms
9999
9999
Function
Low-speed operation command
*1
Remote setting (setting clear)
Middle-speed operation
command
*1
Remote setting (deceleration)
High-speed operation command
*1
Remote setting (acceleration)
*2
0 to 8, 10 to 14, 16, 18, 24, 25, 28, 37 to 40, 46
to 48, 50, 51, 57, 58, 60, 62, 64 to 67, 70 to 73,
77 to 81, 84, 94 to 98, 9999
0 to 8, 10 to 14, 16, 18, 24, 25, 28, 37 to 40, 46
to 48, 50, 51, 57, 58, 61, 62, 64 to 67, 70 to 73,
77 to 81, 84, 94 to 98, 9999
0 to 8, 10 to 14, 16, 18, 24, 25, 28, 37 to 40, 46
to 48, 50, 51, 57, 58, 62, 64 to 67, 70 to 73, 77
to 81, 84, 94 to 98, 9999
Description
Set the time delay for the input terminal response.
No filter for the input terminal
Related parameter
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.44 to Pr.51, Pr.450 to
Pr.463, Pr.569, Pr.832, etc.
Pr.267
Pr.15, Pr.16
Pr.57, Pr.58, Pr.162 to
Pr.165, Pr.299, Pr.611
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.9
5.9 (T) Multi-function input terminal parameters
Setting range
Refer to
page
249
222
249
222
249
222
358
330
248
446,
451
387
252
355
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents