Download  Print this page
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660

Advertisement

00023 00038 00105 00083 00126 00170 00250 00310 00380 00470 00620 00770 00930 01160 01800 02160 02600 03250 03610 04320 04810 05470 06100 06830
Model FR-F840-[]
0.75K 1.5K 2.2K 3.7K 5.5K 7.5K
Trigger level
1.5
2.5
reference current (A)
07700 08660 09620 10940 12120
Model FR-F842-[]
355K 400K 450K 500K 560K
Trigger level
610
683
reference current (A)
 Digital source (monitor item) selection
• Select the digital sources (input/output signals) to be set to Pr.1038 to Pr.1045 from the following table. When a value
other than the ones in the following table is set, "0" (OFF) is applied for indication.
Setting
Signal name
value
0
1
STF
2
STR
3
AU
4
RT
5
RL
6
RM
7
RH
8
JOG
9
MRS
10
STP (STOP)
11
RES
12
CS
21
X0
22
X1
23
X2
24
X3
25
X4
26
X5
27
X6
28
X7
29
X8
30
X9
31
X10
32
X11
33
X12
34
X13
35
X14
36
X15
37
DY
 Trigger setting (Pr.1025, Pr.1035 to Pr.1037, Pr.1046, Pr.1047)
• Set the trigger generating conditions and the trigger target channels.
Pr.1025
setting
0
Trace starts when inverter enters an fault status (protective function activated)
1
Trace starts when analog monitor satisfies trigger conditions
2
Trace starts when digital monitor satisfies trigger conditions
3
Trace starts when either of analog or digital monitor satisfies trigger conditions
4
Trace starts when both of analog or digital monitor satisfies trigger conditions (AND)
• Set the trigger generation conditions for the analog monitor.
Pr.1036
setting
Sampling starts when the analog data targeted for the trigger exceeds the value specified
0
at the trigger level
Sampling starts when the analog data targeted for the trigger falls below the value specified
1
at the trigger level
470
5. PARAMETERS
5.11 (A) Application parameters
11K
15K 18.5K 22K
4
6
9
12
17
23
770
866
962
Remarks
For the details of the signals, refer to
page
355.
For the details of the signals, refer to
the Instruction Manual of the FR-
A8AX (option).
Trigger generating conditions
Trigger generation conditions
30K
37K
45K
55K
75K
31
38
44
57
71
86
Setting
Signal name
value
101
RUN
102
SU
103
IPF
104
OL
105
FU
106
ABC1
107
ABC2
121
DO0
122
DO1
123
DO2
124
DO3
125
DO4
126
DO5
127
DO6
128
RA1
129
RA2
130
RA3
90K 110K 132K 160K 185K 220K 250K 280K 315K
110
144
180
216
260
325
Remarks
For the details of the signals, refer to
page
312.
For the details of the signals, refer to
the Instruction Manual of the FR-
A8AY (option).
For the details of the signals, refer to
the Instruction Manual of the FR-
A8AR (option).
Selection of trigger
target channel
Pr.1035
Pr.1046
Pr.1035, Pr.1046
Pr.1035, Pr.1046
Trigger level setting
Set the trigger level from 600 to
1400 (-400 to 400%
Pr.1037.
361
432
481
547
*1
) in

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: