Use Of A Function Group Number For The Identification Of Parameters - Mitsubishi Electric FR-F820-00046 Instruction Manual

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

*2
The setting range or initial value for the FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower.
*3
The setting range or initial value for the FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
*4
The initial value for the FR-F820-00340(7.5K) or lower and FR-F840-00170(7.5K) or lower.
*5
The initial value for the FR-F820-00490(11K) or higher and FR-F840-00250(11K) or higher.
*6
Differs according to the capacity.
4%: FR-F820-00340(7.5K) or lower and FR-F840-00170(7.5K) or lower
2%: FR-F820-00490(11K) to FR-F820-02330(55K), FR-F840-00250(11K) to FR-F840-01160(55K)
1%: FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher
*7
The value for the 200 V class.
*8
The value for the 400 V class.
*9
The parameter number in parentheses is the one for use with the LCD operation panel and the parameter unit.
*10 The setting range or initial value for the standard model.
*11 The setting range or initial value for the separated converter type.
*12 The setting range or initial value for the IP55 compatible model.
*13 The setting is available for the standard structure model or the separated converter type.
*14 The setting is available for the standard structure model and the IP55 compatible model.
*15 The setting is available when the PLC function is enabled.
5.1.2
Use of a function group number for the
identification of parameters
A parameter identification number shown on the PU can be switched from a parameter number to a function group number.
As parameters are grouped by function and displayed by the group, the related parameters can be set continually at a time.
 Changing a parameter identification number to a function group number
Pr.MD setting
0
1
2
Operating procedure
1.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
2.
Selecting the parameter setting mode
Press
segment LCD display.)
3.
Selecting a parameter
Turn
Press
4.
Selecting the use of the function group number
Turn
setting. "
156
5. PARAMETERS
5.1 Parameter list
Description
The setting of parameter identification number remains the same as
the last setting.
The parameter number is used for the identification of parameters,
and displayed in numerical order.
The function group number is used for the identification of
parameters, and displayed in alphanumeric order.
to choose the parameter setting mode. (The parameter number read previously appears on the 12-
until "
" (Group parameter setting) appears.
to confirm the selection. The setting "
to change the set value to "
" and "
" are displayed alternately after the setting is completed.
"(initial value) will appear.
" (function group number). Press
to confirm the Group parameter