Mitsubishi Electric FR-F820-00046 Instruction Manual page 642

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Pr.
Name
Output current detection signal delay
151
time
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection during
154
stall prevention operation
RT signal function validity condition
155
selection
156
Stall prevention operation selection
157
OL signal output timer
158
AM terminal function selection
Automatic switchover frequency range
159
from bypass to inverter operation
160
User group read selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
163
First cushion time for restart
164
First cushion voltage for restart
Stall prevention operation level for
165
restart
Output current detection signal
166
retention time
Output current detection operation
167
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/batch
172
clear
173
User group registration
174
User group clear
178
STF terminal function selection
179
STR terminal function selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
185
JOG terminal function selection
186
CS terminal function selection
187
MRS terminal function selection
188
STOP terminal function selection
189
RES terminal function selection
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
ABC1 terminal function selection
196
ABC2 terminal function selection
232
Multi-speed setting (8 speed)
233
Multi-speed setting (9 speed)
234
Multi-speed setting (10 speed)
235
Multi-speed setting (11 speed)
236
Multi-speed setting (12 speed)
237
Multi-speed setting (13 speed)
*1
Instruction code
Control method
Exte
Read Write
V/F
V/F
V/F
nded
33
B3
1
34
B4
1
35
B5
1
36
B6
1
37
B7
1
38
B8
1
39
B9
1
3A
BA
1
3B
BB
1
00
80
2
01
81
2
02
82
2
03
83
2
04
84
2
05
85
2
06
86
2
07
87
2
0A
8A
2
0B
8B
2
0C
8C
2
0D
8D
2
0E
8E
2
12
92
2
13
93
2
14
94
2
15
95
2
16
96
2
17
97
2
18
98
2
19
99
2
1A
9A
2
1B
9B
2
1C
9C
2
1D
9D
2
1E
9E
2
1F
9F
2
20
A0
2
21
A1
2
22
A2
2
23
A3
2
24
A4
2
28
A8
2
29
A9
2
2A
AA
2
2B
AB
2
2C
AC
2
2D
AD
2
9.3 Parameters (functions) and instruction codes under different control methods
*2
*3
Copy
Magnetic flux
Magnetic flux
Magnetic flux
PM
PM
PM
×
×
×
×
×
×
×
×
×
Parameter
All
1
*3
Clear
*3
clear
2
3
4
5
×
6
7
8
×
9
×
×
×
×
10
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
641
9. APPENDIX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents