Mitsubishi Electric FR-F820-00046 Instruction Manual page 148

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Pr.
Function
Pr.
group
SF-PR slip amount
674
G061
adjustment gain
User parameter auto storage
675
A805
function selection
684
C000
Tuning data unit switchover
686
E712
Maintenance timer 2
Maintenance timer 2 warning
687
E713
output set time
688
E714
Maintenance timer 3
Maintenance timer 3 warning
689
E715
output set time
Second free thermal
692
H011
reduction frequency 1
Second free thermal
693
H012
reduction ratio 1
Second free thermal
694
H013
reduction frequency 2
Second free thermal
695
H014
reduction ratio 2
Second free thermal
696
H015
reduction frequency 3
699
T740
Input terminal filter
702
C106
Maximum motor frequency
Induced voltage constant
706
C130
(phi f)
707
C107
Motor inertia (integer)
711
C131
Motor Ld decay ratio
712
C132
Motor Lq decay ratio
Starting resistance tuning
717
C182
compensation
Starting magnetic pole
721
C185
position detection pulse
width
724
C108
Motor inertia (exponent)
Motor protection current
725
C133
level
726
N050
Auto Baudrate/Max Master
727
N051
Max Info Frames
Device instance number
728
N052
(Upper 3 digits)
Device instance number
729
N053
(Lower 4 digits)
Second motor induced
738
C230
voltage constant (phi f)
739
C231
Second motor Ld decay ratio 0 to 100%, 9999
740
C232
Second motor Lq decay ratio 0 to 100%, 9999
Second starting resistance
741
C282
tuning compensation
Second motor magnetic pole
742
C285
detection pulse width
Second motor maximum
743
C206
frequency
Second motor inertia
744
C207
(integer)
Second motor inertia
745
C208
(exponent)
Second motor protection
746
C233
current level
Name
Setting range
0 to 500%
1, 9999
0, 1
0 (1 to 9998)
0 to 9998, 9999
0 (1 to 9998)
0 to 9998, 9999
0 to 590 Hz, 9999
1 to 100%
0 to 590 Hz, 9999
1 to 100%
0 to 590 Hz, 9999
5 to 50 ms, 9999
0 to 400 Hz, 9999
0 to 5000 mV (rad/s),
9999
10 to 999, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
16000 μs, 9999
0 to 7, 9999
100 to 500%, 9999
0 to 255
1 to 255
0 to 419 (0 to 418)
0 to 9999 (0 to 4302)
0 to 5000 mV (rad/s),
9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
16000 μs, 9999
0 to 400 Hz, 9999
10 to 999, 9999
0 to 7, 9999
100 to 500%, 9999
Minimum
Initial value
Refer
setting
to page
FM
CA
increments
0.1%
100%
534
1
9999
462
366,
1
0
375
1
0
212
1
9999
212
1
0
212
1
9999
212
0.01 Hz
9999
252
1%
100%
252
0.01 Hz
9999
252
1%
100%
252
0.01 Hz
9999
252
1 ms
9999
355
0.01 Hz
9999
375
0.1 mV
9999
375
(rad/s)
1
9999
375
0.1%
9999
375
0.1%
9999
375
0.1%
9999
375
1 μs
9999
375
1
9999
375
0.1%
9999
375
1
255
511
1
1
511
1
0
511
1
0
511
0.1 mV
9999
375
(rad/s)
0.1%
9999
375
0.1%
9999
375
0.1%
9999
375
1 μs
9999
375
0.01 Hz
9999
375
1
9999
375
1
9999
375
0.1%
9999
375
5. PARAMETERS
5.1 Parameter list
Customer
1
setting
2
3
4
5
6
7
8
9
10
147

Hide quick links:

Advertisement

Table of Contents
loading