5.8.2
Monitor indicator selection using operation
panel or via communication
The monitored item to be displayed on the operation panel or the parameter unit can be selected.
Pr.
Name
52
Operation panel main
M100
monitor selection
774
Operation panel monitor
M101
selection 1
775
Operation panel monitor
M102
selection 2
776
Operation panel monitor
M103
selection 3
992
Operation panel setting dial
M104
push monitor selection
170
Watt-hour meter clear
M020
563
Energization time carrying-
M021
over times
268
Monitor decimal digits
M022
selection
891
Cumulative power monitor
M023
digit shifted times
171
Operation hour meter clear
M030
564
Operating time carrying-
M031
over times
290
Monitor negative output
M044
selection
1106
Torque monitor filter
M050
1107
Running speed monitor
M051
filter
1108
Excitation current monitor
M052
filter
(M) Monitor display and monitor output signal
Initial value
Setting range
0, 5 to 14, 17, 18, 20,
0
23 to 25, 34, 38, 40 to 45,
(output
50 to 57, 61, 62, 64, 67,
frequency)
68, 81 to 96, 98, 100
1 to 3, 5 to 14, 17, 18, 20,
23 to 25, 34, 38, 40 to 45,
9999
50 to 57, 61, 62, 64, 67,
68, 81 to 96, 98, 100,
9999
0 to 3, 5 to 14, 17, 18, 20,
0
23 to 25, 34, 38, 40 to 45,
(Set
50 to 57, 61, 62, 64, 67,
frequency)
68, 81 to 96, 98, 100
0
10
9999
9999
(0 to 65535)
0
(Read-only)
0
9999
1
9999
0 to 4
9999
9999
0
9999
9999
(0 to 65535)
0
(Read-only)
0
0 to 7
0 to 5 s
9999
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
Description
Select the monitor to be displayed on the
operation panel and the parameter unit.
Refer to
page 264
for the monitor
description.
The output frequency, output current and
output voltage monitor that are displayed
in monitor mode on the operation panel
and the parameter unit can be switched to
a specified monitor.
9999: Follows the Pr.52 setting.
Select the monitor to be displayed when
the setting dial on the operation panel is
pushed.
Set "0" to clear the watt-hour meter
monitor.
Set the maximum value for monitoring via
communication. Set it in the range of 0
and 9999 kWh.
Set the maximum value for monitoring via
communication. Set it in the range of 0
and 65535 kWh.
Displays the numbers of times that the
cumulative energization time monitor
exceeded 65535 h. Read-only.
Displays as integral value.
Displays in 0.1 increments.
No function
Set the number of times to shift the
cumulative power monitor digit.
The monitor value is clamped at the
maximum value.
No shift
Monitor value is cleared when it exceeds
the maximum value.
Set "0" to clear the operation hour
monitor.
The read value is always 9999. Nothing
happens when "9999" is set.
Displays the numbers of times that the
operating time monitor exceeded 65535
h. Read-only.
Set the availability of output with a minus
sign for the terminal AM, the operation
panel display, or monitoring via
communication. (Refer to
page
272)
The filter time constant is selectable for
monitoring of the torque. A larger setting
results in slower response.
0.3 s filter
The filter time constant is selectable for
monitoring of the running speed. A larger
setting results in slower response.
0.08 s filter
The filter time constant is selectable for
monitoring of the motor excitation current.
A larger setting results in slower
response.
0.3 s filter
PARAMETERS
5
GROUP
M
263