5. PARAMETERS
5.8 (M) Item and output signal for monitoring
Signal
Function
name
Fault output 3 (Power-OFF
Y91
signal)
Energy saving average value
Y92
updated timing
Y93
Current average monitor
ALM2
Fault output 2
Y95
Maintenance timer
REM
Remote output
LF
Alarm
ALM
Fault
FDN2
Second PID lower limit
FUP2
Second PID upper limit
Second PID forward/reverse
RL2
rotation output
Second During PID control
PID2
activated
During second PID output
SLEEP2
shutoff
Y205
Second PID deviation limit
Cooling fan operation
Y206
command
Y207
Control circuit temperature
PS
PU stopped
LUP
Upper limit warning detection
LDN
Lower limit warning detection
During load characteristics
Y213
measurement
Y215
During cleaning
Operation
Outputted when the Fault occurs due to an
inverter circuit fault or connection fault.
Switches between ON and OFF every time
the average energy saving is updated during
the energy saving monitoring. This signal
cannot be assigned to any of the relay output
terminal (Pr.195, Pr.196, Pr.320 to Pr.322).
Outputted in pulses for transmission of the
average current value and the maintenance
timer value. This signal cannot be assigned to
any of the relay output terminal (Pr.195,
Pr.196, Pr.320 to Pr.322).
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs).
The signal output continues during the
inverter reset and stops after the inverter
*6
reset finishes.
Outputted when the value of Pr.503 reaches
the Pr.504 setting or higher.
Outputted via a terminal by setting a proper
number in a relative parameter.
Outputted when an Alarm fault (fan fault or a
communication error) occurs.
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs). The signal output
stops when the inverter reset starts.
Outputted when the input value is lower than
the lower limit set for the second PID control
operation.
Outputted when the input value is higher than
the upper limit set for the second PID control
operation.
Outputted during forward rotation operation
in the second PID control operation.
Outputted during the second PID control
operation.
Outputted while the second PID output
suspension function is activated.
Outputted when the absolute deviation value
exceeds the limit value during the second PID
control operation.
Outputted when the cooling fan operation is
commanded.
Outputted when the temperature of the
control circuit board reaches the detection
level or higher.
Outputted while the PU is stopped.
Outputted when the load fault upper limit
warning is detected.
Outputted when the load fault lower limit
warning is detected.
Outputted during measurement of the load
characteristics.
Outputted during operation of the cleaning
function.
Refer
Related
to
parameter
page
319
Pr.52, Pr.54,
Pr.158, Pr.891 to
306
Pr.899
Pr.555 to Pr.557
213
319
Pr.503, Pr.504
212
Pr.495 to Pr.497
324
258,
Pr.121, Pr.244
478
319
Pr.753 to Pr.758
401
Pr.753 to Pr.758,
Pr.1147 to
Pr.1149
Pr.753 to Pr.758,
Pr.1145, Pr.1146
Pr.244
258
Pr.663
329
Pr.75
188
Pr.1480 to
281
Pr.1492
Pr.1469 to
398
Pr.1479