Download  Print this page
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660

Advertisement

Setting
Positive
Negative
logic
logic
91
191
92
192
93
193
94
194
95
195
96
196
98
198
99
199
200
300
201
301
202
302
203
303
204
304
205
305
206
306
207
307
208
308
211
311
212
312
213
313
215
315
316
5. PARAMETERS
5.8 (M) Item and output signal for monitoring
Signal
Function
name
Fault output 3 (Power-OFF
Y91
signal)
Energy saving average value
Y92
updated timing
Y93
Current average monitor
ALM2
Fault output 2
Y95
Maintenance timer
REM
Remote output
LF
Alarm
ALM
Fault
FDN2
Second PID lower limit
FUP2
Second PID upper limit
Second PID forward/reverse
RL2
rotation output
Second During PID control
PID2
activated
During second PID output
SLEEP2
shutoff
Y205
Second PID deviation limit
Cooling fan operation
Y206
command
Y207
Control circuit temperature
PS
PU stopped
LUP
Upper limit warning detection
LDN
Lower limit warning detection
During load characteristics
Y213
measurement
Y215
During cleaning
Operation
Outputted when the Fault occurs due to an
inverter circuit fault or connection fault.
Switches between ON and OFF every time
the average energy saving is updated during
the energy saving monitoring. This signal
cannot be assigned to any of the relay output
terminal (Pr.195, Pr.196, Pr.320 to Pr.322).
Outputted in pulses for transmission of the
average current value and the maintenance
timer value. This signal cannot be assigned to
any of the relay output terminal (Pr.195,
Pr.196, Pr.320 to Pr.322).
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs).
The signal output continues during the
inverter reset and stops after the inverter
*6
reset finishes.
Outputted when the value of Pr.503 reaches
the Pr.504 setting or higher.
Outputted via a terminal by setting a proper
number in a relative parameter.
Outputted when an Alarm fault (fan fault or a
communication error) occurs.
Outputted when the inverter's protective
function is activated to stop the power output
(when the Fault occurs). The signal output
stops when the inverter reset starts.
Outputted when the input value is lower than
the lower limit set for the second PID control
operation.
Outputted when the input value is higher than
the upper limit set for the second PID control
operation.
Outputted during forward rotation operation
in the second PID control operation.
Outputted during the second PID control
operation.
Outputted while the second PID output
suspension function is activated.
Outputted when the absolute deviation value
exceeds the limit value during the second PID
control operation.
Outputted when the cooling fan operation is
commanded.
Outputted when the temperature of the
control circuit board reaches the detection
level or higher.
Outputted while the PU is stopped.
Outputted when the load fault upper limit
warning is detected.
Outputted when the load fault lower limit
warning is detected.
Outputted during measurement of the load
characteristics.
Outputted during operation of the cleaning
function.
Refer
Related
to
parameter
page
319
Pr.52, Pr.54,
Pr.158, Pr.891 to
306
Pr.899
Pr.555 to Pr.557
213
319
Pr.503, Pr.504
212
Pr.495 to Pr.497
324
258,
Pr.121, Pr.244
478
319
Pr.753 to Pr.758
401
Pr.753 to Pr.758,
Pr.1147 to
Pr.1149
Pr.753 to Pr.758,
Pr.1145, Pr.1146
Pr.244
258
Pr.663
329
Pr.75
188
Pr.1480 to
281
Pr.1492
Pr.1469 to
398
Pr.1479

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: