Mitsubishi Electric FR-F820-00046 Instruction Manual page 645

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Pr.
391
Receive time interval at heart beat
392
Event driven detection width
414
PLC function operation selection
415
Inverter operation lock mode setting
416
Pre-scale function selection
417
Pre-scale setting value
418
Extension output terminal filter
434
Network number (CC-Link IE)
435
Station number (CC-Link IE)
450
Second applied motor
453
Second motor capacity
454
Number of second motor poles
455
Second motor excitation current
456
Rated second motor voltage
457
Rated second motor frequency
458
Second motor constant (R1)
459
Second motor constant (R2)
Second motor constant (L1) / d-axis
460
inductance (Ld)
Second motor constant (L2) / q-axis
461
inductance (Lq)
462
Second motor constant (X)
Second motor auto tuning setting/
463
status
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
498
PLC function flash memory clear
Communication error execution
500
waiting time
Communication error occurrence
501
count display
Stop mode selection at
502
communication error
503
Maintenance timer 1
Maintenance timer 1 warning output
504
set time
505
Speed setting reference
Emergency drive dedicated waiting
514
time
515
Emergency drive dedicated retry count
522
Output stop frequency
523
Emergency drive mode selection
524
Emergency drive running speed
MODBUS RTU communication check
539
time interval
Frequency command sign
541
selection
Communication station number (CC-
542
Link)
543
Baud rate selection (CC-Link)
544
CC-Link extended setting
547
USB communication station number
USB communication check time
548
interval
549
Protocol selection
NET mode operation command source
550
selection
644
9. APPENDIX
9.3 Parameters (functions) and instruction codes under different control methods
Instruction code
Name
Read Write
5B
5C
0E
0F
10
11
12
22
23
32
35
36
37
38
39
3A
3B
3C
3D
3E
3F
5F
60
61
62
00
01
02
03
04
05
0E
0F
16
17
18
27
29
2A
2B
2C
2F
30
31
32
*1
Control method
Exte
Magnetic flux
Magnetic flux
Magnetic flux
V/F
V/F
V/F
nded
DB
3
DC
3
8E
4
8F
4
90
4
91
4
92
4
A2
4
A3
4
B2
4
B5
4
×
B6
4
×
B7
4
×
B8
4
×
B9
4
×
BA
4
×
BB
4
×
BC
4
×
BD
4
×
BE
4
×
BF
4
×
DF
4
E0
4
E1
4
E2
4
80
5
81
5
82
5
83
5
84
5
85
5
8E
5
8F
5
96
5
97
5
98
5
A7
5
A9
5
AA
5
AB
5
AC
5
AF
5
B0
5
B1
5
B2
5
*2
Parameter
*3
Copy
PM
PM
PM
×
×
×
×
×
×
×
×
All
*3
Clear
*3
clear
×
×
×
*4
*4
*4
*4
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4

Hide quick links:

Advertisement

Table of Contents
loading