Check And Clear Of The Fault History - Mitsubishi Electric FR-F820-00046 Instruction Manual

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

6.3

Check and clear of the fault history

The operation panel stores the fault indications which appear when a protective function is activated to display the fault record
for the past eight faults. (Fault history)
 Check for the fault history
Monitor mode
Fault history mode
Fault record 1
Fault record 2
Fault record 8
When the fault history is
empty, "E0" is displayed.
*1
When an overcurrent trip occurs by an instantaneous overcurrent, the monitored current value saved in the fault history may be lower than the
actual current that has flowed.
*2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
564
6. PROTECTIVE FUNCTIONS
6.3 Check and clear of the fault history
Parameter setting mode
[Operation for displaying fault history]
The last eight fault records can be displayed.
(On the display of the last fault record (fault record 1), a decimal point LED is ON.)
Press the
setting dial.
Fault record number
Latest fault
Fault record number
Second fault in past
Press the
setting dial.
Fault record number
Eighth fault in past
Press the
setting dial.
Function mode
Output frequency
Blinking
Time
Blinking
Day
Blinking
Month
Blinking
Output current ∗1
Blinking
Output voltage
Blinking
Cumulative
energization time ∗2
Blinking
Year
Blinking

Hide quick links: